64 Rainger Linear
OPERATION
Open Delivery
Start Up - Electric Cord / Motor Pump Applications
1. Inspect the wheel tracks to insure no vehicles or
other equipment will be contacted upon start-up
or operation.
2. If the machine has below ground guidance, turn
the oscillator ON.
3. Connect electric cord to power source. Refer to
Open Delivery Electric Cord Handling and Op-
eration beginning on page 65, then return to
this instruction and continue with step 4.
4. Check the centrifugal pump oil reservoir level.
5. Move the cart disconnect panel switch to the ON
position.
6. Move the pump panel disconnect switch to the
ON position.
7. Turn the control panel disconnect switch to the
ON position.
8. Check the voltmeter reading and verify that the
Nominal Supply Voltage is correct for this ma-
chine. See Figure 64-1.
9. Determine if the machine will be run wet or dry.
• If running the machine wet, with water:
(a) Lower suction inlet into ditch until the inlet
lift cables go slack. See Figure 64-2.
(b) Prime the centrifugal pump. See 50/60 Hz
AC Voltage Electric Primer on page 61.
After the pump is primed return to this
instruction and continue with step (c).
(c) Start the pump using the control panel.
Refer to the appropriate Control Panel
Owner’s Manual for control panel operat-
ing procedures.
(d) Slowly fill the system with water. Slowly
open the riser valve so that the pump
does not loose prime.
(e) Refer to the appropriate Control Panel
Owner’s Manual for control panel operat-
ing procedures.
(f) Also refer to Open Delivery Electric Cord
Handling and Operation beginning on
page 67 as needed.
• If running the machine dry, without water:
(a) Make sure the suction inlet is raised out of
the ditch/water,
(b) Refer to the appropriate Control Panel
Owner’s Manual for control panel operat-
ing procedures.
(c) Also refer to Open Delivery Electric Cord
Handling and Operation beginning on
page 67 as needed.
!
CAUTION
• DO NOT OPERATE THE MACHINE IF THE
VOLT METER READS BELOW THE MINIMUM
ALLOWED VOLTAGE OR ABOVE THE MAXI-
MUM ALLOWED VOLTAGE. SEE FIGURE 64-2.
• OPERATING THE MACHINE OUTSIDE THESE
LIMITS COULD CAUSE DAMAGE TO THE
DRIVE MOTORS AND OTHER ELECTRICAL
COMPONENTS.
• CORRECT THE LOW VOLTAGE PROBLEM
BEFORE RESUMING OPERATION.
Nominal
Supply Voltage
Maximum
Allowed Voltage
Minimum
Allowed Voltage
480 VAC @ 60Hz
505 VAC
440 VAC
415 VAC @ 50Hz
420 VAC
375 VAC
400 VAC @ 50Hz
420 VAC
365 VAC
380 VAC @ 50Hz
420 VAC
355 VAC
Figure 64-1
1
3
2
Figure 64-2 1. Suction Inlet
2. Ditch
3. Lift Cable
Содержание Rainger Linear
Страница 2: ...2 Rainger Linear This page was left blank intentionally...
Страница 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Страница 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Страница 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...