Rainger Linear 55
OPERATION
Center Inlet
Hose and Cord Positioning
6. At the machine/control panel:
(a) Set the direction of travel.
(b) Set the percentage timer to the desired application rate or speed.
7. When ready, start the machine. If applicable, start pipeline pump and open the water shut off valve for the
hose. The machine should start and run in the desired direction and stop at the end of field/hose stop post
which was set for the length of the hose.
8. If applicable, prepare the second hose by connecting the riser end to the pipeline shut off valve. Position second
hose approximately 15 ft (4.57 m) from the center of the linear cart toward the pipeline. See Figure 55-1.
9. Allow the linear cart to move past the end of the second hose approximately 50 ft (15.24 m). Stop the
machine. See Figure 55-1.
Depending on the type of center inlet do one of the
following:
•
If this is a single inlet:
(a) Close the water shut off valve for the first
hose.
(b) Select the opposite direction of travel, start
the system, and run until tension on the first
hose is relaxed. Stop the system.
(c) Disconnect the first hose from the pipeline
shut off valve so that water from the hose
drains away from the cart path.
(d) Disconnect chains for first hose from cart
and disconnect first hose from center inlet.
(e) Connect the inlet end of second hose to the
single hose center inlet with circle lock ring.
Attach chains from the soft hose/poly hose
connection to the anchor bracket on each
side of cart.
•
If this is a double inlet:
(a) Connect the inlet end of second hose to the center inlet with circle lock ring. Attach chains from the soft
hose/poly hose connection to the anchor bracket on each side of cart. See Figure 55-2.
(b) Open the water shut off valve for the second hose and close the water shut off valve for the first hose.
(c) Disconnect the first hose from the pipeline shut off valve so that water from the hose drains away from
the cart path.
(d) Select the opposite direction of travel, start the system, and run until tension on the first hose is relaxed.
Stop the system.
(e) Disconnect chains for first hose from cart and disconnect first hose from center inlet.
1
4
3
2
1
5
6
6
7
8
Figure 55-1 1. Shut Off Valve
2. First Hose
3. Center Inlet
4. Second hose
5. Electric Cord
6. Power Pedestal
7. Alternate Power Pedestal Location and Electric Cord Position
8. Direction of Travel
1
2
4
5
4
3
Figure 55-2 1. Second Hose
2. Center Inlet
3. Circle Lock Ring
4. Chain
5. Anchor Bracket
* Double Inlet Shown
Содержание Rainger Linear
Страница 2: ...2 Rainger Linear This page was left blank intentionally...
Страница 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Страница 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Страница 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...