TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
System will not hold the safety.
Drive unit out of alignment, breaking
the Span Safety Box switch.
Move drive unit back into alignment
and determine cause.
Flat or low tire causing misalign-
ment of drive units.
Repair or replace.
Gearbox motor failure.
Contact your local Valley dealer.
Electrical component failure.
Contact your local Valley dealer.
Center drive gearbox failure.
Repair or replace.
Wheel gearbox failure.
Repair or replace.
Drive shaft/U-joint failure.
Repair or replace.
Guidance control box microswitch
failure.
Contact your local Valley dealer.
Pulse tower box microswitch
failure.
Contact your local Valley dealer.
Span safety box microswitch
failure.
Contact your local Valley dealer.
Machine not positioned correctly
with guidance system.
Align the machine, then attempt
to restart in the opposite direction
of travel to align the machine with
guidance system.
Oscillator power supply failure.
Contact your local Valley dealer.
System holds safety, but the end
tower will not move in the run
mode.
Low pressure switch defective.
Contact your local Valley dealer.
Bad relay on relay board.
Contact your local Valley dealer.
Machine shut down in-line.
Engine/generator stopped.
Check fuel supply.
Check fuel filter.
Check water separator.
Check oil level.
If no problems are discovered, turn
the control panel disconnect to the
off position and attempt to restart
the engine/generator.
Incoming power failure.
Call the power company.
Plug pulled out of receptacle.
Make sure the cord is long
enough.
Make sure the end of cord stop is
set correctly.
Loss of water pressure.
Check pump for proper operation.
Low voltage or intermittent low
voltage.
Engine RPM too slow.
Adjust the engine/generator as
needed. Refer to the engine/gen-
erator owner/operator’s manual.
Intermittent excessive load.
Attempt restart of machine. If the
machine restarts, monitor the
voltage and continue operation.
Operation
Содержание Rainger Linear
Страница 2: ...2 Rainger Linear This page was left blank intentionally...
Страница 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Страница 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Страница 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...