12 TECHNICAL DATA
12.1 Ratings and Capacity
12.2 Domestic Hot Water Specifications
*Max DHW temp 140° F (60° C)
12 - RATINGS AND CAPACITIES
Item
MACF-115
MACF-150
MACF-205
Input Ratings (MBH)
Min
16.6
22
29.5
Max
115.5
153
205
Output Ratings
(MBH)
Min
15.3
19
26
Max
105.5
136
180
Domestic Water Pressure
2.9 psi (0.2 bar) - 116 psi (8.0 bar)
Minimum Flow Rate
0.55 GPM
0.50 GPM
Maximum Flow Rate
2.64 gpm
3.50 gpm
5.00 gpm
Flow Rate 77°F (43°C) Temp. Rise
2.35 gpm
3.25 gpm
4.65 gpm
DHW Supply Connection Size
1/2"BSPT at
boiler or 1/2"
Copper Sweat**
1/2" NPT
3/4" NPT
Cold Water Input Connection Size
1/2" BSPT at
boiler or 1/2"
Copper Sweat**
1/2" NPT
3/4" NPT
**1/2" Copper stub adapters included with boiler
Model
Number
CH Input, MBH
(1)
(1)(2)
CH
Heating
Capacity, MBH *
(1)(3)
Net AHRI
Rating Water,
MBH
(2)
AFUE%
Maximum
Minimum
MAHF-100
93.5
16.6
85.4
74
95.0
MACF-115
93.5
16.6
85.4
74
95.0
MAHF-125
125
22
113
98
95.0
MACF-150
125
22
113
98
95.0
MAHF-165
164
29.5
153
133
95.0
MACF-205
164
29.5
153
133
95.0
(1) 1000 Btu/hr (British Thermal Units Per Hour)
(2) Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) are based on DOE (Department of Energy) test
procedures.
(3) Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler
for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping
systems, etc.
*Max CH Supply temp 176° F (80°C)
240013371 REV B, [10/01/2021]
Содержание MACF-115
Страница 2: ...MACF 150 ...
Страница 4: ...MAHF 125 ...
Страница 74: ...70 A 1 MODEL 100 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 75: ...71 A 2 MODEL 125 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 76: ...72 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013371 REV B 10 01 2021 ...
Страница 77: ...73 APPENDIX A WIRING DIAGRAMS A 4 MODEL 115 Combi 240013371 REV B 10 01 2021 ...
Страница 78: ...74 A 5 MODEL 150 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 79: ...75 A 6 MODEL 205 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 80: ...76 NOTES 240013371 REV B 10 01 2021 ...
Страница 81: ...77 NOTES 240013371 REV B 10 01 2021 ...
Страница 82: ...78 NOTES 240013371 REV B 10 01 2021 ...
Страница 117: ...33 MODEL 100 Heat Only 100 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 118: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 119: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 120: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Comb PN 240012875 REV C 10 01 2021 ...
Страница 121: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 122: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 127: ...43 LOW WATER CUTOFF DETAIL LOW WATER CUTOFF NO NO YES PN 240012875 REV C 10 01 2021 ...
Страница 132: ...48 3 FAULT SOLUTION SECTIONS PN 240012875 REV C 10 01 2021 ...
Страница 135: ...51 Parameter ID Changed From Changed To Date Reason PARAMETER CHANGE HISTORY PN 240012875 REV C 10 01 2021 ...