20
5 - COMBUSTION AIR AND VENT PIPING
100/115/125/150
Vent
Type
Vent Size
Vent
Material
Intake
(L1)
Exhaust
(L2)
Combined Vent
(L1+L2)
Max
Min
Max
Min
Max
Min
Twin
Pipe
2"
(60 mm)
Polypropylene
85 ft
(25.9 m)
6 ft
(1.8 m)
85 ft
(25.9 m)
6 ft
(1.8 m)
170 ft
(51.8 m)
12 ft
(3.6 m)
3"
(80 mm)
Polypropylene
49 ft
(15 m)
6 ft
(1.8 m)
147 ft
(45 m)
6 ft
(1.8 m)
196 ft
(60 m)
12 ft
(3.6 m)
Flexible
Exhaust* w/
Rigid 3" PP
Intake
CPVC**
(PVC optional
on intake
ONLY)
Coaxial
Vent Size
Material
Natalini
DuraVent
Centrotherm
Max
Min
Max
Min
Max
Min
2"/4"
(60 mm/100 mm)
Polypropylene
32.8 ft
(10 m)
6 ft
(1.8 m)
27.88 ft
(8.5 m)
6 ft
(1.8 m)
24.60 ft
(8.5 m)
6 ft
(1.8 m)
3"/5"
(80 mm/128 mm)
*For vertical runs only
**In Canada ULC S636 and in the USA UL1738 schedule 40 CPVC are the only approved Vent Material to be used as
an alternative to Polypropylene venting for the exhaust pipe.
VENT MATERIAL OPTIONS
(Maximum Equivalent Vent Length Shown)
165/205
Vent
Type
Vent Size
Vent
Material
Intake
(L1)
Exhaust
(L2)
Combined Vent
(L1+L2)
Max
Min
Max
Min
Max
Min
Twin
Pipe
2"
(60 mm)
Polypropylene
85 ft
(25.9 m)
6 ft
(1.8 m)
85 ft
(25.9 m)
6 ft
(1.8 m)
170 ft
(51.8 m)
12 ft
(3.6 m)
3"
(80 mm)
Polypropylene
100 ft
(30.5 m)
6 ft
(1.8 m)
100 ft
(30.5 m)
6 ft
(1.8 m)
200 ft
(60.9 m)
12 ft
(3.6 m)
Flexible
Exhaust* w/
Rigid 3" PP
Intake
CPVC**
(PVC optional
on intake
ONLY)
Coaxial
Vent Size
Material
Natalini
DuraVent
Centrotherm
Max
Min
Max
Min
Max
Min
2"/4"
(60 mm/100 mm)
Polypropylene
3"/5"
(80 mm/128 mm)
32.8 ft
(10 m)
6 ft
(1.8 m)
32.8 ft
(10 m)
6 ft
(1.8 m)
32.8 ft
(10 m)
6 ft
(1.8 m)
*For vertical runs only
**In Canada ULC S636 and in the USA UL1738 schedule 40 CPVC are the only approved Vent Material to be used as
an alternative to Polypropylene venting for the exhaust pipe
240013371 REV B, [10/01/2021]
Содержание MACF-115
Страница 2: ...MACF 150 ...
Страница 4: ...MAHF 125 ...
Страница 74: ...70 A 1 MODEL 100 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 75: ...71 A 2 MODEL 125 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 76: ...72 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013371 REV B 10 01 2021 ...
Страница 77: ...73 APPENDIX A WIRING DIAGRAMS A 4 MODEL 115 Combi 240013371 REV B 10 01 2021 ...
Страница 78: ...74 A 5 MODEL 150 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 79: ...75 A 6 MODEL 205 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 80: ...76 NOTES 240013371 REV B 10 01 2021 ...
Страница 81: ...77 NOTES 240013371 REV B 10 01 2021 ...
Страница 82: ...78 NOTES 240013371 REV B 10 01 2021 ...
Страница 117: ...33 MODEL 100 Heat Only 100 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 118: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 119: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 120: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Comb PN 240012875 REV C 10 01 2021 ...
Страница 121: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 122: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 127: ...43 LOW WATER CUTOFF DETAIL LOW WATER CUTOFF NO NO YES PN 240012875 REV C 10 01 2021 ...
Страница 132: ...48 3 FAULT SOLUTION SECTIONS PN 240012875 REV C 10 01 2021 ...
Страница 135: ...51 Parameter ID Changed From Changed To Date Reason PARAMETER CHANGE HISTORY PN 240012875 REV C 10 01 2021 ...