8.STATISTICS
・
ACCUMULATION CONTROL FUNCTION
62
8-5. Auto Accumulation Command
When Complete output signal turns ON, do auto accumulation to the active weighing code, value,
times and statistical data. Also send out auto printer command via SI/F and SI/FII interfaces.
But if the weighing result exceeds 99999 or selected comparison OFF in Over/Under Comparison of
the Function, F805AT-CK do not do accumulation.
Timing of auto accumulation command
1) Dynamic mode
Near zero
Measurement
Measurement
Measurement
Near zero
Taking in
Over
t1
ON
Go
Under
Complete
OFF
ON
OFF
ON
ON
Accumulation
ON
t1: Complete output time
start mode
start
reset
Содержание F805AT-CK
Страница 1: ...F805AT CK CHECKER SCALE CONTROLLER OPERATION MANUAL 01 Sep 2022 Rev 1 05...
Страница 129: ......