12.INTERFACE
84
12-3-4. Communication format
R command
- Reading out the Gross weight (sign, 5-digits weight value, decimal point)
- Reading out the Net weight (sign, 5-digits weight value, decimal point)
- Reading out the Tare (sign, 5-digits weight value, decimal point)
- Status 1 (7-digits)
- Status 2 (7-digits)
- Status 3 (7-digits)
HOST
F805AT-CK
R A
R A
+
1
0
0
0
0
.
CR
CR
LF
HOST
F805AT-CK
R B
R B
+
1
0
0
0
0
.
CR
CR
LF
HOST
F805AT-CK
R C
R C
+
1
0
0
0
0
.
CR
CR
LF
HOST
F805AT-CK
R D
R D
0
0
0
0
0
0
0
CR
CR
LF
Undefined
Weight value
Zero alarm
Weight value
Stable
Tare subtracted
1:ON
0:OFF
1:ON
0:OFF
1:ON
0:OFF
LOCK
(soft)
Rear panel
LOCK
1:ON
0:OFF
1:ON
0:OFF
Weight display
3: Error
2: Result
1: Net
0: Gross
HOST
F805AT-CK
R E
R E
0
0
0
0
0
0
0
CR
CR
LF
Undefined
Near zero
Output signal
Taking in
Output signal
Complte
1:ON
0:OFF
1:ON
0:OFF
1:ON
0:OFF
Over
Output signal
Go
Output signal
1:ON
0:OFF
1:ON
0:OFF
Under
1:ON
0:OFF
Output signal
Output signal
HOST
F805AT-CK
R F
R F
0
0
0
0
0
0
0
CR
CR
LF
Undefined
Upper limit
Output signal
1:ON
0:OFF
Total limit
Output signal
Lower limit
Output signal
1:ON
0:OFF
1:ON
0:OFF
Содержание F805AT-CK
Страница 1: ...F805AT CK CHECKER SCALE CONTROLLER OPERATION MANUAL 01 Sep 2022 Rev 1 05...
Страница 129: ......