7.FUNCTION AS A WEIGHT CHECKER
54
7-4. Sequence Mode
7-4-1. Empty count/ Take in count
1) EMPTY COUNT
This is the interval between the measurement start and actual data acquisition.
One count corresponds to 5msec. (200 counts = 1 sec.)
When using the dynamic mode, set
“
0
”
in principle.
(input range: 0 ~ 999)
2) TAKE IN COUNT
This is the interval during which the weight value is actually acquired after
the measurement start and the passage of the EMPTY COUNT interval.
One count corresponds to 5msec. (200 counts = 1 sec.)
When the weight value is acquired by the TAKE IN COUNT, weighing is
completed.
(Weighing is also completed when the weight value becomes the NEAR
ZERO set value or less.)
(input range: 1 ~ 999)
Operation
7-4-2. Average mode/ Sample mode
1) AVERAGE MODE
Select whether to calculate the average by using the taken-in data from
which the maximum group and minimum group are removed or calculate
the average by using all the data.
Select from REMOVAL / ARITHMETIC.
REMOVAL
Out of sample data, splitting the difference between the maximum value
and minimum value of the eight. The average is calculated by using data
with the removal of the data of the maximum group
⑧
larger than
effective maximum value and the minimum group
①
smaller than
effective minimum value.
In this case, the effective maximum value and effective minimum value in
the sample data does not remove.
* The effective maximum value is median value of group
⑦
and group
⑧
.
(Median value is truncated at the less than effective display digits.)
The effective minimum value is median value of group
①
and group
②
.
(Median value is truncated at the less than effective display digits.)
ARITHMETIC
The average is calculated by using all the sample data.
MODE
SEQUENCE MODE
→
Press
EMPTY COUNT
→
1)
→
Input 0 ~ 999
OK
→
MODE
SEQUENCE MODE
→
Press
TAKE IN COUNT
→
2)
→
Input 1 ~ 999
OK
→