6.FUNCTION SETTING
43
6-2-4. Weighing code selection/ Setting code selection
The F805AT-CK has two types of codes: codes to perform weighing (weighing codes) and codes to
make settings (setting codes).
The selection of Weighing Code and Setting Code should be performed by External Part (Control
Connector) or Internal part (Front Panel Key).
Selection with Internal or External part can also be decided from external selection (SELECTION).
1) Weighing code selection
2) Setting code selection
1: KEY SPECIFY
Specify a code No. by using the touch panel.
KEY INPUT
(It can be changed through serial communications, such as RS-232C.)
2: EXTERNAL INPUT
Specify a code No. by external (control connector) input.
3: SELECTION
Either key input or external input can be set by the condition of
external (control connector) input.
Operation
Setting code "05"
Weighing code "10"
While weighing with the Setting Value of Code "10",
the Setting Value of Code "05" can be changed.
INTERNAL
0
9
EXTERNAL
EXTERNAL SELECTION
CONTROL
MODE
FUNCTION
→
→
Press
WEIGHING CODE SELECTION
→
Select KEY SPECIFY/ EXTERNAL INPUT/ SELECTION
OK
→
1)
MODE
FUNCTION
→
→
Press
SETTING CODE SELECTION
→
Select KEY INPUT/ EXTERNAL INPUT/ SELECTION
OK
→
2)
Содержание F805AT-CK
Страница 1: ...F805AT CK CHECKER SCALE CONTROLLER OPERATION MANUAL 01 Sep 2022 Rev 1 05...
Страница 129: ......