1.FEATURES OF F805AT-CK
4
1-3. Points to be Noted in Measuring
Filter settings
Adjust the “DIGITAL FILTER” and “ANALOG FILTER” in the “OPERATION” settings, and set
optimum values so as to remove noise components, such as vibration, and to obtain sufficient rising
characteristics.
The relationship between parameter changes, stability, and response is as shown in the table below.
(Refer to "6-1-2. Digital filter" on Page37, "6-1-3. Analog filter" on Page37.)
Prevention of double placement
Double placement is a state in which two or more measuring objects are placed on the load-sensing part.
Take the distance (
d
) between measuring objects longer than the load-sensing part (
l
). Be aware that
accurate weighing cannot be performed especially in “DYNAMIC MODE”. (Refer to Fig. 5.)
Long measuring objects
Compared with shorter measuring objects, longer ones cause the entire load to be applied to the load
cell for a shorter time.
Adjust the belt speed, etc., so that a sufficient data count can be obtained. (Refer to Fig. 6.)
Setting of ANALOG FILTER
Low frequency
High frequency
Stability
Stable
⇔
Unstable
Response
Slow
⇔
Fast
Setting of DIGITAL FILTER
High count
Low count
Stability
Stable
⇔
Unstable
Response
Slow
⇔
Fast
F
Near zero
0
t
NET
[Figure 5]
d
l
E
F
◇
Example of double placement (
d
<
l
)
There is a possibility that
E
the near zero may not be applied.
0
t
NET
[Figure 6]
G
G'
H
H'
T
G
T
H
(T
G
>
T
H
)