Alarm Detection Capabilities
9.5
Alarm Detection Capabilities
The fault detection functions shown in Table 9-6 "Table of Alarms" and Table 9-7 "Table of
Warnings" are incorporated for protection in the event of a problem with the turbo molecular
pump or controller.
When an error is detected, check the ALARM lamp (Fig. 2-2 (5)) and refer to Section 9.5.3 for
the appropriate remedy.
9.5.1 Movement in Alarm Detection Capabilities (ALARM)
1. ALARM lamp (Fig. 2-2 (5)) lights.
2. The logic interface "ALARM" signal turn on.
3. The pump start the protective operations shown in Table 9-6 "Table of Alarms".
9.5.2 Movement in Alarm Detection Capabilities (WARNING)
1. ALARM lamp (Fig. 2-2 (5)) flashes.
2. The logic interface "WARNING" signal turn on.
3. Pump operation continues.
9.5.3 Reset Procedure
1. Refer to the Troubleshooting information and eliminate the cause of the problem.
2. Conduct the reset operation.
3. (ALARM) If the problem has been eliminated, the ALARM lamp (Fig. 2-2 (5)) goes out, the
"ALARM" logic interface signals turn off after an alarm was given, the pump rotor coasts.
(WARNING) When the problem is eliminated after a warning occurred, pump operation
continues.
4. If the problem was not completely eliminated, the alarm is not cancelled.
Содержание UTM300B
Страница 8: ...vii Location of label...
Страница 11: ...x This page is intentionally left blank...
Страница 17: ...xvi Table of contents This page is intentionally left blank...
Страница 30: ...CONSTRUCTION AND PRINCIPLE 3 1 Pump Construction 3 2 Principle of Turbo Molecular Pumping 3 3 Control system 3...
Страница 51: ...34 SECTION 5 INSTALLATION This page is intentionally left blank...
Страница 70: ...GAS PURGE 7...
Страница 77: ...60 SECTION 8 TURBO MOLECULAR PUMP RECONDITION This page is intentionally left blank...
Страница 111: ...A 26 Appendix A COMMUNICATIONS This page is intentionally left blank...
Страница 113: ...This page is intentionally left blank...