- 76 -
(5)
Operable input format
DIP switch No. 1 OFF
Operation item
In normal state
(remote OFF)
In remote
operation
DIP switch No. 1 ON
Only remote operation
SYSTEM START
START/STOP, test switch
input
Same as right
→
Signal
input
SYSTEM STOP
START/STOP
switch
input
Same as right
→
Signal
input
TEST START
TEST switch
input
Same as right
→
Signal
input
TEST STOP
VENT switch
input
Same as right
→
Signal
input
AUTO ZERO
Auto zero switch
input
Same as right
→
Signal input, auto zero
switch
input
CALIBRATION
Enter with
after
selecting mode switch
.
Same as right
→
Signal input, enter with
after selecting mode
switch
.
PRINT OUT
Return switch
input
Same as right
→
Signal input, enter with
return switch
.
Parameter setting
Enter with return switch
after selecting mode switch
.
Message clear
Enter with the return switch
.
SETPOINT L
Outputted regardless of local operation or remote operation.
SETPOINT H
Outputted regardless of local operation or remote operation.
START UP OK
Outputted regardless of local operation or remote operation.
SYSTEM ERROR
Outputted regardless of local operation or remote operation.
-0
Outputted regardless of local operation or remote operation.
Содержание HELIOT 301