30A168
MODEL PAR-3-H GAS FRYER
F. OPERATING CONTROLS:
The “basic” PAR-3-H gas fryer is equipped with an Electronic Thermostat and Default-to-Manual-Restart (DTMR) control;
However customers may request the fryer be equipped with an “optional” Ultrastat Cooking Computer, such as an Ultrastat 11,21
or 25 Cooking Computer. When applicable, operating instructions for the Ultrastat Cooking Computer will be provided with the
fryer. Operating controls on the Model PAR-3-H gas fryer include the Toggle
ON/OFF
Switch,
AMBER
Power Indicator Lamp,
RED
Burner Indicator Lamp, and the applicable Temperature Controller. These controls are mounted on the Temperature Control
Access Panel; and the Electronic Thermostat and other fryer controls are located behind the access door. The main drain valve and
shortening return levers are located behind the Service Access Panel. These controls were identified in the illustrations shown on
the previous page.
G. AUTOMATIC SAFETY FEATURES:
1. High limit thermostat to shut off gas to the main burners by opening a solenoid-actuated safety valve in the combination gas
control valve.
2. Combination gas control valve which includes a built-in pressure regulator and manual valve.
3. Sensing circuit within the spark ignitor module to turn gas to the fryer
OFF
if a burner
FLAME OUT
occurs.
4. A Drain Valve Safety Switch and a Default-to-Off circuit in the Default-to-Manual-Restart (DTMR) Control that will
DIS-
ABLE
the fryer each time the drain valve is
OPENED
.
5. An
AIR PRESSURE
switch to open the electrical circuit to the spark ignitor and gas valve which will turn the gas to the fryer
OFF
in the event the blower motor fails.
H. RATING PLATE:
Information on this plate includes the model and serial number; BTU/HR input rating of the burners; gas manifold pressure in
inches W.C. ; minimum inlet gas required, orifice size; and type of gas. This data is essential for proper identification when com-
nicating with ULTRAFRYER SYSTEMS or requesting special parts or information. The rating plate is located on the inside of the
Service Access door.
THE FRYER MUST BE CONNECTED ONLY TO THE TYPE OF GAS IDENTIFIED ON THIS RATING PLATE!
Page 5 of 56
Содержание F-P20-18
Страница 5: ...30A168 GENERAL INFORMATION Page 1 of 56...
Страница 11: ...30A168 PRE INSTALLATION Page 7 of 56...
Страница 13: ...30A168 RECEIVING INSTALLING Page 9 of 56...
Страница 18: ...30A168 INITIAL START UP Page 14 of 56...
Страница 22: ...30A168 ABBREVIATED OPERATING INSTRUCTIONS Page 18 of 56...
Страница 24: ...30A168 ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 56...
Страница 26: ...30A168 PREVENTIVE MAINTENANCE TROUBLESHOOTING Page 22 of 56...
Страница 29: ...30A168 CLEANING Page 25 of 56...
Страница 34: ...30A168 FRYER OPERATION Page 30 of 56...
Страница 37: ...30A168 FILTER TUB ASSEMBLY INSTALLATION Page 33 of 56...
Страница 39: ...30A168 FILTERING POLISHING SHORTENING Page 35 of 56...
Страница 42: ...30A168 SHORTENING BOIL OUT DISPOSAL INSTALLATION Page 38 of 56...
Страница 46: ...30A168 TECHNICAL ASSISTANCE ORDERING INFORMATION Page 42 of 56...
Страница 48: ...30A168 RECOMMENDED SPARE PARTS Page 44 of 56...
Страница 50: ...30A168 PARTS IDENTIFICATION Page 46 of 56...
Страница 52: ...30A168 ULTRAFRYER MODEL PAR 3 H GAS FRYER FRONT VIEW Page 48 of 56...
Страница 59: ...30A168 WIRING DIAGRAMS Page 55...