30A168
e. EXIT MELT BUTTON
-
When this button is momentarily depressed, the melt cycle timing module in the
DTMR’s Default-To-Melt circuit will switch to the FULL-ON position allowing the Electronic Thermostat
to heat shortening to it’s PRE-SET temperature.
D. DTMR OPERATION -
Prior to operating the gas fryer,
ENSURE
the Filter Tub Assembly is properly installed and
DOCKED
to the fryer’s Bulkhead socket and the Temperature Control Access Door is closed, the fryer vat is filled with
shortening to the middle of the
“E”
in the word
LEVEL
of the shortening level mark on the rear wall of the vat; then:
1. Turn the Toggle ON/OFF Power Switch to the
OFF
Position.
2. Turn the
MANUAL
gas valve to the
OFF
position and wait
FIVE
(5) minutes for any accumulated gas to disperse.
3.
ENSURE
the
MAIN
gas shut-off valve is in the
ON
posi-
tion, and that the
EXHAUST FAN
is
ON.
4.
Turn the
MANUAL
gas valve to the
ON
position.
ITEM
ACTION
DTMR CONDITION
1
ENSURE
the drain valve is in the CLOSED
UP
position and that shortening is at the proper level;
then turn the Toggle ON/OFF switch to the
ON
posi-
tion.
A.
AMBER
power lamp will
LIGHT
.
B.
BLUE READY
TO START lamp will
LIGHT.
CAUTION: PRIOR TO PROCEEDING TO STEP 2 VISUALLY CHECK THAT THE HEAT ELEMENT IS
COVERED WITH AT LEAST 2" (51 mm) OF SHORTENING.
2
Depress, then release the momentary
START
button.
A.
RED STARTED
lamp and
AMBER MELT
MODE
lamp will light.
B.
BLUE READY TO START
lamp will turn
OFF.
C. The
MELT CYCLE TIMING MODULE
in the
Default-To-Melt electrical circuit will begin
cycling the fryer heat mechanism
ON
for twelve
(12) seconds and
OFF
for 28 seconds to safely
heat the shortening.
CAUTION: PRIOR TO PROCEEDING TO STEP 3, VISUALLY CHECK THAT THE SHORTENING
COMPLETELY COVERS THE HEAT MECHANISM.
3
Depress, then release the momentary
EXIT MELT
button.
A.
AMBER MELT MODE
lamp will turn
OFF,
RED STARTED
lamp will remain lit.
B. The
Melt Cycle Timing Module
in the
Default-To-Melt circuit will switch to the
FULL
ON
position allowing the Electronic Thermostat
to heat shortening to its pre-set temperature.
4
When the fryer’s pre-set temperature has been
reached, initiate a cook cycle.
Page 32 of 56
Содержание F-P20-18
Страница 5: ...30A168 GENERAL INFORMATION Page 1 of 56...
Страница 11: ...30A168 PRE INSTALLATION Page 7 of 56...
Страница 13: ...30A168 RECEIVING INSTALLING Page 9 of 56...
Страница 18: ...30A168 INITIAL START UP Page 14 of 56...
Страница 22: ...30A168 ABBREVIATED OPERATING INSTRUCTIONS Page 18 of 56...
Страница 24: ...30A168 ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 56...
Страница 26: ...30A168 PREVENTIVE MAINTENANCE TROUBLESHOOTING Page 22 of 56...
Страница 29: ...30A168 CLEANING Page 25 of 56...
Страница 34: ...30A168 FRYER OPERATION Page 30 of 56...
Страница 37: ...30A168 FILTER TUB ASSEMBLY INSTALLATION Page 33 of 56...
Страница 39: ...30A168 FILTERING POLISHING SHORTENING Page 35 of 56...
Страница 42: ...30A168 SHORTENING BOIL OUT DISPOSAL INSTALLATION Page 38 of 56...
Страница 46: ...30A168 TECHNICAL ASSISTANCE ORDERING INFORMATION Page 42 of 56...
Страница 48: ...30A168 RECOMMENDED SPARE PARTS Page 44 of 56...
Страница 50: ...30A168 PARTS IDENTIFICATION Page 46 of 56...
Страница 52: ...30A168 ULTRAFRYER MODEL PAR 3 H GAS FRYER FRONT VIEW Page 48 of 56...
Страница 59: ...30A168 WIRING DIAGRAMS Page 55...