30A168
A. FILTERING SHORTENING
1. Turn the
TOGGLE ON / OFF SWITCH
to the fryer
OFF
, turn the
MANUAL GAS
VALVE OFF
, and ensure the filter
tub is properly docked beneath the drain valve.
NOTE:
Pull on the filter tub Handle to
ASSURE
the male docking plug is
SEATED
in the female bulkhead socket.
2. Place the amount of
FILTER AGENT
into the fryer vat as prescribed in the cleaning manual provided by your chemical
supplier; thoroughly stir the filter agent into the shortening using a skimmer; then skim the shortening to remove any
floating crumbs.
CAUTION: PRIOR TO PROCEEDING TO THE NEXT STEP, PUT ON SAFETY GOGGLES, NEOPRENE INSULATED GLOVES
AND AN APRON.
3. Carefully attach the drain valve handle to the drain valve; then open the drain valve by turning the
DRAIN VALVE
HANDLE
slightly downward. When the bottom of the filter tub is covered with about two (2) inches of shortening,
completely
OPEN
the drain valve, and while shortening is draining, scrape all sides of the vat to remove encrusted
material using the scraper.
4. When all shortening has drained into the filter tub, use the
DRAIN ROD
to stand the wire rack on one side of the vat.
5. Use the drain rod to pull the sediment on the bottom of the vat towards the valve opening, then use the rod to push sedi-
ment through the valve opening.
CAUTION: DO NOT ACTIVATE (TURN) THE VAT SHORTENING RETURN LEVER AND TOPSIDE SHORTENING LEVER AT
THE SAME TIME! TO DO SO WILL REDUCE SHORTENING FLOW.
6.
If there is
NO
sediment or debris visible on the heat exchanger or bottom of the vat,
CLOSE
the drain valve; then
turn the
LEFT HAND
Vat Shortening Return Lever
1⁄4 turn counter clock wise
to automatically return shortening in
the filter tub through the
SWEEP NOZZLE
in the bottom of the vat. When all shortening has been returned to the
vat, turn the
LEFT HAND
Vat Shortening Return Lever
1⁄4 turn clockwise
to stop the flow of shortening; then pro-
ceed to page 41.
7.
If there is considerable sediment and debris on the bottom of the vat
, FLUSH
this sediment from vat using the Wash
Down Hose or
OPTIONAL
Automatic Vat Cleaner (AVC) also referred to as
SPRAY BLASTER
, as described below.
a. Fryer
WITHOUT
an Automatic Vat Cleaner (AVC) <Spray Blaster>
1) Leave the drain valve in the
OPEN
position,
CAREFULLY
connect the Wash Down Hose
Male
In-Line Plug to the
TOPSIDE FEMALE SOCKET
; then place the Wash Down Hose nozzle into vat and hold it firmly against an inner
wall so it will not recoil upward when the pump comes on.
2) Turn the
RIGHT HAND
Topside Shortening Return Lever
1⁄4 turn counter clock wise
and hold the hose nozzle at
a 45˚ angle from the bottom of the vat causing sediment and debris to bounce off the rear wall and flow towards
the drain valve.
��� ����������
������ �����
������ �������
������� ����������
������ �����
������ �����
����� �����
�������
������� ������
Page 36 of 56
Содержание F-P20-18
Страница 5: ...30A168 GENERAL INFORMATION Page 1 of 56...
Страница 11: ...30A168 PRE INSTALLATION Page 7 of 56...
Страница 13: ...30A168 RECEIVING INSTALLING Page 9 of 56...
Страница 18: ...30A168 INITIAL START UP Page 14 of 56...
Страница 22: ...30A168 ABBREVIATED OPERATING INSTRUCTIONS Page 18 of 56...
Страница 24: ...30A168 ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 56...
Страница 26: ...30A168 PREVENTIVE MAINTENANCE TROUBLESHOOTING Page 22 of 56...
Страница 29: ...30A168 CLEANING Page 25 of 56...
Страница 34: ...30A168 FRYER OPERATION Page 30 of 56...
Страница 37: ...30A168 FILTER TUB ASSEMBLY INSTALLATION Page 33 of 56...
Страница 39: ...30A168 FILTERING POLISHING SHORTENING Page 35 of 56...
Страница 42: ...30A168 SHORTENING BOIL OUT DISPOSAL INSTALLATION Page 38 of 56...
Страница 46: ...30A168 TECHNICAL ASSISTANCE ORDERING INFORMATION Page 42 of 56...
Страница 48: ...30A168 RECOMMENDED SPARE PARTS Page 44 of 56...
Страница 50: ...30A168 PARTS IDENTIFICATION Page 46 of 56...
Страница 52: ...30A168 ULTRAFRYER MODEL PAR 3 H GAS FRYER FRONT VIEW Page 48 of 56...
Страница 59: ...30A168 WIRING DIAGRAMS Page 55...