30A168
3) Use the “L” shaped brush to push the sediment through the drain valve to keep the drain clear. Hose off the heat
exchanger and vat walls until all sediment and debris has been flushed through the drain into the filter tub.
4) Turn the
RIGHT HAND
Topside Shortening Return Lever
1⁄4 turn counter clock wise
; then
CAREFULLY
remove the Wash Down Hose
MALE
In-Line Plug from the
TOPSIDE FEMALE SOCKET
by depressing
the Topside Socket Release Knob.
5)
Hang the Wash Down Hose in an up-right position so shortening can drain into a metal container; then proceed
to paragraph B 1 below.
b. Fryer
WITH
an Automatic Vat Cleaner (AVC).
1) With the Drain Valve in the
OPEN
position,
CAREFULLY
place the AVC (Spray Blaster) on the fryer’s
TOPSIDE
HANGER BRACKET
and
SECURELY
connect the
MALE
In-Line Plug on the AVC to the
TOPSIDE FEMALE
SOCKET
.
2) Turn the
RIGHT HAND
Topside Shortening Return Lever
1⁄4 turn counter clock wise
to allow shortening in the
filter tub to be discharged into the vat through the four (4) nozzles in the bottom of the spray blaster, flushing
sediment and debris through the drain valve. When all sediment and debris has been flushed from the vat, turn the
Topside Shortening Return Lever
1⁄4 turn clock wise
, remove the male in-line plug on the Spray Blaster from the
Topside Female Socket by depressing the Topside Release Knob.
3. CAREFULLY
remove the
HOT
Automatic Vat Cleaner from the hanger bracket, and
THOROUGHLY
clean it in a
3 compartment sink.
4. Proceed to paragraph B 1 below.
������� ������
������� ����
������� ������
�������
������� ������
������ ��� ���������
������ ������
B. POLISHING SHORTENING
1. Set a timer for the amount of time established for
POLISHING
shortening, then turn the
VAT SHORTENING RETURN
LEVER
1/4 TURN COUNTER CLOCKWISE
to allow shortening to circulate through the system to
POLISH
the shortening.
CAUTION: DO NOT POLISH THE SHORTENING MORE THAN THE ESTABLISHED TIME AS IT WILL PUMP EXCESS AIR
INTO THE SHORTENING CAUSING SHORTENING BREAKDOWN.
2. At the end of the established time,
TURN
the
VAT SHORTENING
RETURN LEVER
1/4 TURN CLOCKWISE
, turn the
DRAIN VALVE HANDLE
to the closed
UP
position; replace the grill in the fryer; then
TURN
the Vat Shortening
RETURN
LEVER
1/4 COUNTER CLOCKWISE
to automaticlly return shortening in the filter tub to the fryer vat.
3. When all shortening in the filter tub has been returned to the fryer,
TURN
the
VAT SHORTENING
RETURN LEVER
,
1/4
TURN CLOCKWISE
check and if necessary add fresh shortening so shortening is level with the middle line of the letter
“E”
in the word
LEVEL
of the shortening level mark on the rear wall of the fryer.
4. Remove the Filter Tub Assembly by pressing the
DOCKING RELEASE HANDLE
and pulling the
STANDPIPE DOCKING
HANDLE ASSY
away from the
FEMALE
Bulkhead Socket adjacent to the Drain Valve; then
THOROUGHLY
clean,
assemble and replace the Filter Tub Assembly in the fryer cabinet.
Page 37 of 56
Содержание F-P20-18
Страница 5: ...30A168 GENERAL INFORMATION Page 1 of 56...
Страница 11: ...30A168 PRE INSTALLATION Page 7 of 56...
Страница 13: ...30A168 RECEIVING INSTALLING Page 9 of 56...
Страница 18: ...30A168 INITIAL START UP Page 14 of 56...
Страница 22: ...30A168 ABBREVIATED OPERATING INSTRUCTIONS Page 18 of 56...
Страница 24: ...30A168 ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 56...
Страница 26: ...30A168 PREVENTIVE MAINTENANCE TROUBLESHOOTING Page 22 of 56...
Страница 29: ...30A168 CLEANING Page 25 of 56...
Страница 34: ...30A168 FRYER OPERATION Page 30 of 56...
Страница 37: ...30A168 FILTER TUB ASSEMBLY INSTALLATION Page 33 of 56...
Страница 39: ...30A168 FILTERING POLISHING SHORTENING Page 35 of 56...
Страница 42: ...30A168 SHORTENING BOIL OUT DISPOSAL INSTALLATION Page 38 of 56...
Страница 46: ...30A168 TECHNICAL ASSISTANCE ORDERING INFORMATION Page 42 of 56...
Страница 48: ...30A168 RECOMMENDED SPARE PARTS Page 44 of 56...
Страница 50: ...30A168 PARTS IDENTIFICATION Page 46 of 56...
Страница 52: ...30A168 ULTRAFRYER MODEL PAR 3 H GAS FRYER FRONT VIEW Page 48 of 56...
Страница 59: ...30A168 WIRING DIAGRAMS Page 55...