background image

 

Thank you for choosing Dura Access Control Equipment (DACE). We welcome you to the ever growing community 

of happy DACE product owners. The advanced engineering and high-quality construc2on of each DACE product 

we build is something of which we are proud.

 

The Ul2ma gate operator is packed with features to bring you more convenience and to enhance your security.

 

Your owners manual will introduce you to the features and opera2on of your new Ul2ma gate operator. It is sug-

gested that you read it carefully since the informa2on it contains can contribute greatly to the sa2sfac2on you 

receive from your new gate operator.

 

We also recommend that you follow the maintenance schedule so that your operator will give you many years of 

problem free service.

 

Please keep this manual in a safe, convenient place so that you can refer to it from 2me to 2me when performing 

maintenance or ac2va2ng new features. 

Look out for these icons in the instrucon manual: 

Take Careful Note! 

Informa2on that may affect the operator or func2on in a way you did not expect. . 

Good Idea! 

Following this instruc2on might assist in the future or help with the installa2on. 

Warning! 

Informa2on about poten2al hazard/s & detail requiring your special aGen2on. 

Please a0ach your invoice to this manual for future use (see warranty). 

Please read the maintenance schedule for your Ulma operator to ensure its longevity and connuous safe operaon. 

 

 

AC 

Alterna2ng Current (pertaining to a supply voltage)

 

AC 

Auto Close (pertaining to the gate moving)

 

BAC 

Beams Auto Close (Same as PIRAC)

 

DACE 

Dura Access Control Equipment

 

DC 

Direct Current

 

DIY 

Do It Yourself

 

E.C.A 

Electrical Contractors Associa2on

 

FRX 

Free Exit

 

HID 

Human Interface Device (Joys2ck / Speaker / Display)

 

IR 

Infrared 

 

IRBC 

Closing Infrared Beam (Safety Beam) 

 

IRBO 

Opening Infrared Beam (Safety Beam)

 

LCD 

Liquid Crystal Display

 

LED 

Light Emi?ng Diode (Indicator light)

 

Mag 

Magne2c

 

NAV 

Naviga2on

 

PED 

Pedestrian

 

PIRAC 

Passive Infrared Auto Close (Same as BAC)

 

RSSI 

Receiver Signal Strength Indicator

 

RX 

Receiver (or onboard receiver)

 

Trig 

Trigger

 

TX 

TransmiGer

 

ABBREVIATIONS 

FOREWORD 

Содержание HT18/36

Страница 1: ...INSTALLATION USER MANUAL RT25 50 Regular Tra c 12V 24V 25 50m per min 500 300kg HT18 36 High Tra c 12V 24V 18 36m per min 600 300kg Ver 1 01 Proudly manufactured by www dace co za...

Страница 2: ...fety Beams Relay Output 20 11 2 External Radio Receiver Loop Detector 21 11 3 Closing Safety Beam FET Output Relay Output 22 11 4 Opening Safety Beam FET Output Relay Output 23 11 5 Connec2ng Common E...

Страница 3: ...on manual Take Careful Note Informa2on that may a ect the operator or func2on in a way you did not expect Good Idea Following this instruc2on might assist in the future or help with the installa2on Wa...

Страница 4: ...care should be taken when automa2ng a gate that is fully cladded as wind resistance can cause the gate to not close properly Only when all the above points are sa sfactory should you go ahead with in...

Страница 5: ...on of the equipment There are a number of areas that may cause entrapment which could lead to injury ULTIMA TECHNICAL SPECIFICATIONS con2nued AREAS WHERE INJURY OR ENTRAPMENT CAN OCCUR 1 Gate Wheels P...

Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...

Страница 7: ...ued PARTS LIST 1 Tritek Controller 2 Rev Counter Housing 3 12 Volt DC Motor 4 Cam Lock 5 Manual Release Door 6 Founda2on Plate 7 Height adjustment Nuts 8 LCD Interface 9 Joys2ck 10 USB Input 11 Transf...

Страница 8: ...n the operator must not be installed It may be possible to reduce these forces by carrying out maintenance on the gate rail but if not then the operator must not be installed These forces can be measu...

Страница 9: ...e mode the gate may run freely down the slope and present a safety risk The gate should always be level This can be achieved by leveling the track using supports or spacers GATES ON A GRADIENT In circ...

Страница 10: ...e carried out by a quali ed electrician 3 Intercom gate sta2on to operator consult with Intercom supplier for cable requirements 4 Keypad to operator consult with keypad supplier for cable requirement...

Страница 11: ...pull the release pin un2l the lid is free The Lid can now be removed REMOVING THE LID 1 Open the manual release door and rotate the thumb wheel clockwise just un2l the gate begins to move 2 The thumb...

Страница 12: ...Be sure to remove any cement debris around the pinion gear Mount the operator above the ood level or if this is not possible build a small protec2ve wall structure in front of the operator to divert t...

Страница 13: ...lf drilling TEK screws through the slots in the rack 5 To aGach addi2onal rack slide the gate open and repeat the above procedures 6 ALer the rack has been aGached use the Height Adjustment Nuts on th...

Страница 14: ...nt that the gearbox be lled with oil before commissioning the operator Only use SAE75W 90 oil to re ll Oil Level Screw Oil Plug 1 Push the gate to the fully closed posi2on 2 Place the magnet on the ra...

Страница 15: ...OUT3 this output must be connected to a Relay Module SA001 for switching Pillar lights Strobe warning lights Explore the LCD menus to adjust the many di erent op2ons available RELAY this output is us...

Страница 16: ...y di er ent op2ons available LOOP this input is typically used in a business complex where a vehicle drives over a Ground Loop to trigger the gate open This input can be made inac2ve through the Time...

Страница 17: ...17 MAINS 220 240V AC HOUSE EARTH WARNING WHEN USING A SOLAR PANEL DISCONNECT THE TRANSFORMER NOT POLARITY SENSITIVE CHARGING SUPPLY OPTIONS SOLAR PANEL MAX 40V DC...

Страница 18: ...accessed from this screen This shortcut will take you to the MAIN SETTINGS screen where all the controller features are available REMOTES DOWN South This shortcut will take you straight to the REMOTE...

Страница 19: ...f mul2ple remotes are to be programmed con2nue to hold the Joys2ck UP North un2l all the remotes have been programmed to the operator Please refer to page 30 in this manual to learn more on Remote Se5...

Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...

Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...

Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...

Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...

Страница 24: ...Normally Open N O Normally Open N O Normally Open N C Normally Closed Tamper Switch is CLOSED when the lid is removed PEDESTRIAN OPENING Keypad Receiver Keyswitch FULL OPEN Intercom STATUS LED Interco...

Страница 25: ...25 OUTPUT DEPENDANT ON VOLTAGE OF BATTERY FITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD of 100mA DACE Relay Module DACE Relay Module LIGHT ZONE BYPASS L N CONNECTION FOR RELAY MODULE...

Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...

Страница 27: ...ITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD 300mA DACE Relay Module DACE Relay Module WIRED TX RX ZONE BYPASS SIREN BELL BELL ALARM BUZZ GATE SYNC LIGHT ALARM BUZZ CONNECTING VARIOU...

Страница 28: ...RECEIVER GND TO TRITEK COM GND RECEIVER SAFETY BEAM A WARNING ONLY CONNECT BATT TO ONE MOTOR AS SHOWN OPERATOR CONTROL BOARD NO 1 OPERATOR CONTROL BOARD NO 2 TWO SYNCHRONISED OPERATORS CONNECTED TO ON...

Страница 29: ...IR Reverse If Open IR Reverse is enabled the gate will reverse back to the fully closed posi2on if the Opening Safety Beam is blocked while the gate is opening If it is disabled the gate will only rev...

Страница 30: ...te number seen on the LCD screen during programming and engraving the remote number on the back of the remote This is helpful when you wish to delete a lost stolen remote Add Remotes No groups If a ne...

Страница 31: ...y guard in aGendance It is far less likely that unknown remotes are acci dentally programmed on to the controller Edit Group The TRITEK uses a grouping system for managing remote users This provides a...

Страница 32: ...posi2on This is useful if a Pedestrian Trigger buGon is located some distance away from the gate such as on an intercom inside the building and allows the pedestrian to walk to the gate before it sta...

Страница 33: ...If enabled this func2on will ac2vate the controller s alarm output if any of the Safety Beams are blocked for a period longer than the 2me set in Ambush IR Timer when the gate is in the open ing posi2...

Страница 34: ...ator is lost the magne2c lock will automa2cally unlock Magne2c locks are not suitable for use with solar powered systems Magne2c locks draw large amounts of power which will signi cantly reduce the nu...

Страница 35: ...to be deleted can be entered manually or the controller can be dialled via the phone while this func2on is open to automa2cally delete the number Delete Num By ID Cell phones that are no longer allowe...

Страница 36: ...ontroller Any users added aLer the users were last saved onto the USB Flash Drive or Android device will be lost with this opera2on Save SeOngs This feature will save only the gate se ngs it excludes...

Страница 37: ...he premises by a domes2c worker With Time Manager you can disable any of the 8 Inputs INF CLS INF OPN LCK STP TRIG PED LOOP C LGHT or TAMPER at 2mes you do not wish for that input to be used It is for...

Страница 38: ...then Annually Monthly and nally Weekly Set Start and Stop Day Time and Date Each period requires Start and Stop inputs Depending on the Type of Period this func2on will request days of the week hours...

Страница 39: ...will exert on the gate while opening An Crush Gap 0 0 5m This is a safety feature to prevent the entrapment of people or animals by the gate while closing By enabling this feature the controller will...

Страница 40: ...speed This speed should be high enough that the gate does not stall while closing but slow enough that the gate does not stop abruptly when reaching the fully closed position Close Crawl Distance Adju...

Страница 41: ...colli sion and during the Beam Reverse modes Slow Close Speed Adjusts the speed that the operator will run at when running in Slow Speed in the closed direction The operator runs in Slow Speed when pr...

Страница 42: ...are rmly in place and are not hanging loose Check that the Marker Magnet on the gate is 2ght and not moving If it is moving it must be 2ghtened and the gate limits must be reprogrammed SERVICE SCHEDUL...

Страница 43: ...e controller AUTO LEARN MODE EXITED The Auto Learn 2me expired or the user manually exited Auto Learn mode that was previously enabled SAVING FILE A le is being saved to the USB device LOADING FILE A...

Страница 44: ...nder Gate Setup on the LCD screen and adjust the opening and or closing forces WARNING MESSAGES MESSAGE DESCRIPTION TRIGGER The operator received a trigger signal PEDESTRIAN The operator received a pe...

Страница 45: ...it again MOTOR FUSE BLOWN The controller has detected that the main motor fuse is blown Check to see if blown and replace this with an equivalent 20A fuse Check that the fuse contacts are free from ca...

Страница 46: ...he physical device used to navigate the menu on the controller LCD Screen The graphics screen display on the controller Loop Detector Detects when a vehicle drives over it to trigger the gate open or...

Страница 47: ...e and the end stop Rack A length of gear aGached to the gate which is driven by the pinion gear Receiver Receives a signal from a Remote transmiGer and triggers the operator Remote A hand held device...

Страница 48: ...dant Controller Input Voltage 12V 24V AC or 17V 44V DC Motor Voltage 12V 24V DC Motor Supply BaGery 12 24V or Transformer driven Ba0ery Charger Intelligent mul2 stage charger with automa2c shutdown cu...

Страница 49: ...through it It is the user s responsibility to ensure that there are no objects animals or people that could be damaged or injured near the gate prior to opera2ng it The user must at all 2mes be aware...

Страница 50: ...he respec2ve remote number label the remotes Remote buGon numbers and the func2ons assigned to each see pg 30 Cell phone User numbers see GSM Se ngs on pg 35 Cell PUK numbers associated to the operato...

Страница 51: ...51 NOTES...

Страница 52: ...using components not tested passed or authorised by DACE This warranty does not cover any Acts of God including lightning hail water power surge insect damage corrosion the transport or costs associa...

Отзывы: