16
♦
INF-GND
: this is a dedicated ground, used to connect
certain brands of safety beams that have the capacity of
performing a self test func2on, such as the DuraOp2cs
Wireless Beams.
♦
INF/CLS
: connect to the safety beam relay or FET output
to prevent the gate from CLOSING on a object (collision
preven2on)
♦
INF/OPN
: connect to the safety beam relay or FET output
to prevent the gate from OPENING on an object (collision
preven2on)
♦
+BATT
: this output is used to power up all auxiliary devic-
es. It is capable of sourcing a maximum of 300mA.
C
AUTION
- ensure that any equipment that is connected to this
output is capable of handling the baGery voltage. When
changing from 12V to 24V baGery, this output voltage will
be the same as the baGery voltage.
♦
LCK/STP
: used to ac2vate and deac2vate Holiday Lockout
via a keypad, keyswitch or receiver.
♦
TRIG
: connect a keypad, keyswitch, receiver or intercom
buGon to this input to allow for FULL opening of the gate.
Explore the LCD menus to adjust the many different op-
2ons available.
♦
PED
: connect a keypad, keyswitch, receiver or intercom
buGon to this input to allow for PARTIAL opening of the
gate. Explore the LCD menus to adjust to the many differ-
ent op2ons available.
♦
LOOP
: this input is typically used in a business complex
where a vehicle drives over a Ground Loop to trigger the
gate open. This input can be made inac2ve through the
Time Manager feature.
♦
C/LIGHT
: the Courtesy Light input can be switched on
with a keypad, receiver or a N/O( normally open) push buGon. It is used to switch on ligh2ng through the relay
module (SA001 - OPTIONAL). Explore the LCD menus to adjust the many different op2ons available.
♦
TAMPER
: to alert any tampering, the Ul2ma operator has a receptacle to fit an op2onal Microswitch that can
be connected to the Tamper & Ground inputs. This will trigger the alarm output if lid tampering is detected.
♦
COM-GND
: connect all ground wiring from auxiliary equipment to this input.
♦
STATUS
: fit an external LED in a convenient place to indicate when the gate is closed, open or in mo2on.
♦
ALARM
: this is an output that can be connected to a wired transmiGer to trigger the house alarm or a relay
module that drives a siren. It will be triggered if any of the security func2ons are breached. Explore the LCD
Security menus to adjust the many different op2ons available.
♦
PULSE
: a very useful output that will trigger every 2me the gate is operated. It is typically used to trigger exter-
nal devices such as a buzzer, garden beams bypass or even to synchronise two gates.
OVERVIEW OF LOW POWER INPUTS & OUTPUTS
Содержание HT18/36
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...