AUTO CLOSE SETUP
To prevent accidents, Safety Beams must be used when enabling the Auto Close func2on.
Enable Auto Close
Enabling this func2on allows the gate operator to Auto Close. If the gate is obstructed and Safety Beams
are connected, the Auto Close Time delay will reset when the obstruc2on is removed.
Auto Close Time
This feature delays the closing of the gate when Auto Close is enabled. The delay can be set from 1- 600
seconds. If beams are connected, the 2mer will reset each 2me the beams are blocked.
AC On Full Open
If enabled, the gate will Auto Close from the fully open posi2on.
AC On Part Open
If enabled, the gate will Auto Close if it was stopped while s2ll opening.
AC On Part Close
If enabled, the gate will Auto Close if it was stopped while it was closing.
Allow Party Mode
‘Party Mode’ is a feature which overrides Auto Close. By enabling the Allow Party Mode func2on, it is
possible to place the operator into Party Mode with the Trigger buGon on the remote.
REMOTE SETTINGS
Up to 1024 Remotes can be added to the TRITEK onboard Receiver.
The TRITEK controller uses Remote Grouping for managing remote access. All remotes must be pro-
grammed to a group for it to func2on. By default, all remotes will be programmed to the Master group,
Group 0, unless a new group is created. If groups have been created, the controller will prompt the user
to select the group into which the new remote must be programmed.
If Groups are being used, it is important to keep track of your remotes. This can be done by wri2ng down
the remote number seen on the LCD screen during programming and engraving the remote number on
the back of the remote. This is helpful when you wish to delete a lost/stolen remote.
Add Remotes (No groups)
If a new group has not been created, the controller will prompt for a Program Method by which to add
the new remote/s.
First Method:
Teach Single Func2on to the Remote BuGon. This will program a single func2on to a
buGon. It begins at Func2on 1, which is Trigger, and scrolling leL will run through all the available func-
2ons up to 16. These include Pedestrian Trigger, Alarm Ac2vate, Party Mode, Light Trigger etc.
Having selected the par2cular func2on required, the controller prompts to hold the Joys2ck Up (North)
and, while holding the joys2ck in this posi2on, add the remote/s by pressing the buGon that is required
to perform the selected func2on.
Second Method:
Duplicate Group Func2ons to Remote. This will duplicate the func2ons already setup on
the exis2ng remotes in Group 0 to the new remote now being programmed.
When selected, the controller prompts to hold the Joys2ck Up (North) and, while holding the joys2ck in
this posi2on, the exis2ng func2ons are duplicated onto the new remote by pressing any buGon on it. All
func2ons in Group 0 will be copied onto the new remote.
The default func2on se?ngs for Group 0 are:
1. Trigger
2. Pedestrian Trigger
3. No Func2on
4. No Func2on
5. Holiday Lockout
6. Alarm Ac2vate
7. No Func2on
8. No Func2on
9. Alarm Ac2vate
10. Party Mode
11. No Func2on
12. Light Trigger
13. No Func2on
14. No Func2on
15. Remote Joys2ck
The func&on number relates to the remote bu6on number or
bu6on configura&on as illustrated.
Con2nues……...
1
= 1
2
= 2
3
= 1 + 2
4
= 4
5
= 1 + 4
6
= 2 + 4
7
= 1 + 2 + 4
8
= 8
9
= 1 + 8
10
= 2 + 8
11
= 1 + 8
12
= 4 + 8
13
= 1 + 4 + 8
14
= 2 + 4 + 8
15
= 1 + 2 + 4 + 8
Содержание HT18/36
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...