LIGHT SETTINGS
Courtesy Light
Usually used to switch pillar lights on when the operator is triggered. The light output must be connected
to an EXO Relay Module. Do not connect mains directly to the controller.
Set Light Timer
This function sets the length of time that the light will remain on if the Courtesy Light option is enabled.
Flash On Moving
If enabled, the light connected to the light output on the controller will flash while the gate is moving.
Pre Close Flash
If enabled, the light will start flashing before the gate closes if the ‘Pre Close Delay’ op2on is set, either
via the ‘Pedestrian Entry’ menu or the ‘ Gate Setup -> Run Profile’ menu.
Pre Open Flash
If enabled, the light will start flashing when the gate is ac2vated if the ‘Pre Open Delay’ op2on is set,
either via the ‘Pedestrian Entry’ menu or the ‘Gate Setup -> Run Profile’ menu.
Flashing Speed
This se?ng adjusts the flashing speed of the light from 0.25 - 6 seconds. Different types of lights have
different response 2mes. Incandescent lights might, for instance, need to be flashed slower than LED
lights.
Fluorescent energy saver bulbs should not be used for warning signals. These lights have special circuitry
which may be damaged by flashing the light and might also damage the controller. It is recommended
that either LED, halogen or incandescent lights are used.
SECURITY SETTINGS
The following Alarm Func2ons, if enabled, will ac2vate the controller’s Alarm output. This output, connected via
an EXO Relay Module, can ac2vate a buzzer; siren or house alarm. If a GSM Module is fiGed, all alarm signals will
be transmiGed to selected cell phone numbers.
Ambush Alarm
If enabled, this func2on will ac2vate the controller’s alarm output if any of the Safety Beams are blocked
for a period longer than the 2me set in ‘Ambush IR Timer’, when the gate is in the open/ing posi2on. This
can occur if an intruder blocks the safety beams, when a homeowner enters the property, to prevent the
gate from closing.
Break In Alarm
When enabled, this func2on will ac2vate the controller’s alarm output immediately if any of the Safety
Beams are blocked while the gate is in the closed posi2on. This effec2vely makes the Safety Beams
perform a func2on like that of Perimeter Beams.
Tamper Alarm
If enabled, this func2on will ac2vate the controller’s alarm output if the gate operator’s lid is liLed up.
This feature is only available on operators where the op2onal tamper switch has been installed.
Gate Open Alarm
If enabled, this func2on ac2vates the controller’s alarm output if the gate remains open for a period
longer than the 2me set in ‘Stand Open Time’. This warns the homeowner if the gate is leL open or is
unable to close (could be as a result of a fault or an obstruc2on).
Securi-Lock
If enabled, this func2on will ac2vate the controller’s alarm output if the gate is forced open while in the
closed posi2on.
Important
: To enable this feature, first place the gate in the closed posi2on and move the Marker
Magnet (see pg. 14) from the prescribed posi2on on the gate to right in front of the Marker Sensor (see
pg.7, part number 14). When the feature is enabled the controller will automa2cally re-detect the
Marker Magnet’s posi2on by moving the gate off the marker and returning back to it.
Ambush IR Timer
This 2mer sets the maximum dura2on that the beams may remain blocked while the gate is in the open
posi2on (See Ambush Alarm) before ac2va2ng the controller’s alarm output (1 sec- 5 min).
Con2nues……...
Содержание HT18/36
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...