background image

36 

Deep Sleep 

This func2on places the controller into ‘Deep Sleep’ when the input power supply fails. Internal process-

es, LEDs and external devices connected to the controller are switched off. Receiver response 2me is 

slightly reduced. BaGery standby 2me is increased by ±

 

 1200%. 

Solar Sleep 

If enabled, this func2on allows the controller to enter into the selected sleep mode (Light, Medium or 

Deep) while the input supply voltage is at a normal level. This is an advantage when the controller is 

connected to a solar panel and the maximum amount of energy must be diverted to charging the baGery.

 

 

 

 

USB SETTINGS 

It is recommended that a full backup is made of the controller onto a USB Flash Drive or an Android  

device connected to the USB input. This is par2cularly important when automa2ng a complex so that all 

se?ngs can be restored easily should the operator require repairs or replacement. 
Check the DACE website regularly for Tritek soLware updates. Save the updated soLware on to a USB 

Flash Drive or Android device and update the Tritek controller. Remember to make a full backup of the 

controller before loading the updated soLware. 

Save Users 

Saves all the Remote, Group and Time Management se?ngs onto a USB Flash Drive or Android device. 

Restore Users

 

Restores all the Remote, Group and Time management se?ngs previously saved with the Save Users 

func2on to the controller. 
Any users added aLer the users were last saved onto the USB Flash Drive or Android device will be lost 

with this opera2on. 

Save SeOngs 

This feature will save only the gate se?ngs, it excludes the user se?ngs i.e Remotes, Groups and Time 

Management. A useful feature for a contractor who can cut down setup 2mes by using a file of frequent-

ly applied gate se?ngs 

Restore SeOngs 

Restores the gate se?ngs to the controller previously saved using the Save Se?ngs func2on. 
The Tritek controller, by default, generates a Log File. This is a log of the last 1,024 events. These events 

include user ac2vity, type of opera2on, 2mes, faults, power loss, alarm ac2va2on etc. This can assist with 

fault finding and the tracking of users entering or exi2ng the premises. 

Save Log file 

Saves the Log File to a USB Flash Drive or Android device connected to the USB input. 

Software Update 

Upgrade or downgrade the current version of software to that saved on a USB Flash Drive or Android 

device. The software version must be compatible with the hardware level. 

Save Time Manager

 

Saves the Time Manager settings and times to a USB Flash Drive or Android device connected to the USB 

input.

 

Restore Time Manager

 

This function will restore all the Time Manager settings and times saved using Save Time Manager. 

Backup Controller 

This func2on does a full controller backup and includes Remotes, Groups, Time Management and the 

gate se?ngs and 2mes onto a USB Flash Drive or connected compa2ble Android phone. 

Restore Controller

 

This func2on restores the controller from a full backup. 

……..con2nued 

Содержание HT18/36

Страница 1: ...INSTALLATION USER MANUAL RT25 50 Regular Tra c 12V 24V 25 50m per min 500 300kg HT18 36 High Tra c 12V 24V 18 36m per min 600 300kg Ver 1 01 Proudly manufactured by www dace co za...

Страница 2: ...fety Beams Relay Output 20 11 2 External Radio Receiver Loop Detector 21 11 3 Closing Safety Beam FET Output Relay Output 22 11 4 Opening Safety Beam FET Output Relay Output 23 11 5 Connec2ng Common E...

Страница 3: ...on manual Take Careful Note Informa2on that may a ect the operator or func2on in a way you did not expect Good Idea Following this instruc2on might assist in the future or help with the installa2on Wa...

Страница 4: ...care should be taken when automa2ng a gate that is fully cladded as wind resistance can cause the gate to not close properly Only when all the above points are sa sfactory should you go ahead with in...

Страница 5: ...on of the equipment There are a number of areas that may cause entrapment which could lead to injury ULTIMA TECHNICAL SPECIFICATIONS con2nued AREAS WHERE INJURY OR ENTRAPMENT CAN OCCUR 1 Gate Wheels P...

Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...

Страница 7: ...ued PARTS LIST 1 Tritek Controller 2 Rev Counter Housing 3 12 Volt DC Motor 4 Cam Lock 5 Manual Release Door 6 Founda2on Plate 7 Height adjustment Nuts 8 LCD Interface 9 Joys2ck 10 USB Input 11 Transf...

Страница 8: ...n the operator must not be installed It may be possible to reduce these forces by carrying out maintenance on the gate rail but if not then the operator must not be installed These forces can be measu...

Страница 9: ...e mode the gate may run freely down the slope and present a safety risk The gate should always be level This can be achieved by leveling the track using supports or spacers GATES ON A GRADIENT In circ...

Страница 10: ...e carried out by a quali ed electrician 3 Intercom gate sta2on to operator consult with Intercom supplier for cable requirements 4 Keypad to operator consult with keypad supplier for cable requirement...

Страница 11: ...pull the release pin un2l the lid is free The Lid can now be removed REMOVING THE LID 1 Open the manual release door and rotate the thumb wheel clockwise just un2l the gate begins to move 2 The thumb...

Страница 12: ...Be sure to remove any cement debris around the pinion gear Mount the operator above the ood level or if this is not possible build a small protec2ve wall structure in front of the operator to divert t...

Страница 13: ...lf drilling TEK screws through the slots in the rack 5 To aGach addi2onal rack slide the gate open and repeat the above procedures 6 ALer the rack has been aGached use the Height Adjustment Nuts on th...

Страница 14: ...nt that the gearbox be lled with oil before commissioning the operator Only use SAE75W 90 oil to re ll Oil Level Screw Oil Plug 1 Push the gate to the fully closed posi2on 2 Place the magnet on the ra...

Страница 15: ...OUT3 this output must be connected to a Relay Module SA001 for switching Pillar lights Strobe warning lights Explore the LCD menus to adjust the many di erent op2ons available RELAY this output is us...

Страница 16: ...y di er ent op2ons available LOOP this input is typically used in a business complex where a vehicle drives over a Ground Loop to trigger the gate open This input can be made inac2ve through the Time...

Страница 17: ...17 MAINS 220 240V AC HOUSE EARTH WARNING WHEN USING A SOLAR PANEL DISCONNECT THE TRANSFORMER NOT POLARITY SENSITIVE CHARGING SUPPLY OPTIONS SOLAR PANEL MAX 40V DC...

Страница 18: ...accessed from this screen This shortcut will take you to the MAIN SETTINGS screen where all the controller features are available REMOTES DOWN South This shortcut will take you straight to the REMOTE...

Страница 19: ...f mul2ple remotes are to be programmed con2nue to hold the Joys2ck UP North un2l all the remotes have been programmed to the operator Please refer to page 30 in this manual to learn more on Remote Se5...

Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...

Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...

Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...

Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...

Страница 24: ...Normally Open N O Normally Open N O Normally Open N C Normally Closed Tamper Switch is CLOSED when the lid is removed PEDESTRIAN OPENING Keypad Receiver Keyswitch FULL OPEN Intercom STATUS LED Interco...

Страница 25: ...25 OUTPUT DEPENDANT ON VOLTAGE OF BATTERY FITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD of 100mA DACE Relay Module DACE Relay Module LIGHT ZONE BYPASS L N CONNECTION FOR RELAY MODULE...

Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...

Страница 27: ...ITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD 300mA DACE Relay Module DACE Relay Module WIRED TX RX ZONE BYPASS SIREN BELL BELL ALARM BUZZ GATE SYNC LIGHT ALARM BUZZ CONNECTING VARIOU...

Страница 28: ...RECEIVER GND TO TRITEK COM GND RECEIVER SAFETY BEAM A WARNING ONLY CONNECT BATT TO ONE MOTOR AS SHOWN OPERATOR CONTROL BOARD NO 1 OPERATOR CONTROL BOARD NO 2 TWO SYNCHRONISED OPERATORS CONNECTED TO ON...

Страница 29: ...IR Reverse If Open IR Reverse is enabled the gate will reverse back to the fully closed posi2on if the Opening Safety Beam is blocked while the gate is opening If it is disabled the gate will only rev...

Страница 30: ...te number seen on the LCD screen during programming and engraving the remote number on the back of the remote This is helpful when you wish to delete a lost stolen remote Add Remotes No groups If a ne...

Страница 31: ...y guard in aGendance It is far less likely that unknown remotes are acci dentally programmed on to the controller Edit Group The TRITEK uses a grouping system for managing remote users This provides a...

Страница 32: ...posi2on This is useful if a Pedestrian Trigger buGon is located some distance away from the gate such as on an intercom inside the building and allows the pedestrian to walk to the gate before it sta...

Страница 33: ...If enabled this func2on will ac2vate the controller s alarm output if any of the Safety Beams are blocked for a period longer than the 2me set in Ambush IR Timer when the gate is in the open ing posi2...

Страница 34: ...ator is lost the magne2c lock will automa2cally unlock Magne2c locks are not suitable for use with solar powered systems Magne2c locks draw large amounts of power which will signi cantly reduce the nu...

Страница 35: ...to be deleted can be entered manually or the controller can be dialled via the phone while this func2on is open to automa2cally delete the number Delete Num By ID Cell phones that are no longer allowe...

Страница 36: ...ontroller Any users added aLer the users were last saved onto the USB Flash Drive or Android device will be lost with this opera2on Save SeOngs This feature will save only the gate se ngs it excludes...

Страница 37: ...he premises by a domes2c worker With Time Manager you can disable any of the 8 Inputs INF CLS INF OPN LCK STP TRIG PED LOOP C LGHT or TAMPER at 2mes you do not wish for that input to be used It is for...

Страница 38: ...then Annually Monthly and nally Weekly Set Start and Stop Day Time and Date Each period requires Start and Stop inputs Depending on the Type of Period this func2on will request days of the week hours...

Страница 39: ...will exert on the gate while opening An Crush Gap 0 0 5m This is a safety feature to prevent the entrapment of people or animals by the gate while closing By enabling this feature the controller will...

Страница 40: ...speed This speed should be high enough that the gate does not stall while closing but slow enough that the gate does not stop abruptly when reaching the fully closed position Close Crawl Distance Adju...

Страница 41: ...colli sion and during the Beam Reverse modes Slow Close Speed Adjusts the speed that the operator will run at when running in Slow Speed in the closed direction The operator runs in Slow Speed when pr...

Страница 42: ...are rmly in place and are not hanging loose Check that the Marker Magnet on the gate is 2ght and not moving If it is moving it must be 2ghtened and the gate limits must be reprogrammed SERVICE SCHEDUL...

Страница 43: ...e controller AUTO LEARN MODE EXITED The Auto Learn 2me expired or the user manually exited Auto Learn mode that was previously enabled SAVING FILE A le is being saved to the USB device LOADING FILE A...

Страница 44: ...nder Gate Setup on the LCD screen and adjust the opening and or closing forces WARNING MESSAGES MESSAGE DESCRIPTION TRIGGER The operator received a trigger signal PEDESTRIAN The operator received a pe...

Страница 45: ...it again MOTOR FUSE BLOWN The controller has detected that the main motor fuse is blown Check to see if blown and replace this with an equivalent 20A fuse Check that the fuse contacts are free from ca...

Страница 46: ...he physical device used to navigate the menu on the controller LCD Screen The graphics screen display on the controller Loop Detector Detects when a vehicle drives over it to trigger the gate open or...

Страница 47: ...e and the end stop Rack A length of gear aGached to the gate which is driven by the pinion gear Receiver Receives a signal from a Remote transmiGer and triggers the operator Remote A hand held device...

Страница 48: ...dant Controller Input Voltage 12V 24V AC or 17V 44V DC Motor Voltage 12V 24V DC Motor Supply BaGery 12 24V or Transformer driven Ba0ery Charger Intelligent mul2 stage charger with automa2c shutdown cu...

Страница 49: ...through it It is the user s responsibility to ensure that there are no objects animals or people that could be damaged or injured near the gate prior to opera2ng it The user must at all 2mes be aware...

Страница 50: ...he respec2ve remote number label the remotes Remote buGon numbers and the func2ons assigned to each see pg 30 Cell phone User numbers see GSM Se ngs on pg 35 Cell PUK numbers associated to the operato...

Страница 51: ...51 NOTES...

Страница 52: ...using components not tested passed or authorised by DACE This warranty does not cover any Acts of God including lightning hail water power surge insect damage corrosion the transport or costs associa...