NOTIFICATION MESSAGES
MESSAGE
DESCRIPTION
MARKER OK
The Marker Magnet just passed the Marker Sensor and registered.
ARMED
One or more of the alarm inputs is armed and will trigger the alarm output if a valid
alarm condi2on occurs.
ADD A MINIMUM OF TWO
REMOTES TO MASTER
GROUP
Some func2ons require a minimum of two remotes in the Master Group for safety
reasons. A remote belonging to the Master Group is some2mes needed to unlock a
feature e.g. locking the Remote Menu to prevent more remotes from being taught
to the system.
MENU LOCK
RELEASED
The Menu Lock was released. the menu may now be entered at any 2me. This will
happen if either the Menu Lock was disabled or there are less than two remotes
belonging to the Master Group.
PRESS MASTER GROUP
REMOTE BUTTON
A buGon from a remote belonging to the Master Group must be pressed to con2n-
ue the current opera2on.
RECEIVER LOCKED, ONLY
MASTER REMOTES AL-
LOWED
If the receiver is locked, only remotes belonging to the master group will be allowed
to func2on.
BEAMS OK
A beams Self Test was performed and the beams are working.
NO TIME PERIODS IN
MEMORY
The user wanted to clear a 2me period but there aren’t any in memory.
NEW TX LEARNED
A new remote or device was learned to the controller.
AUTO LEARN MODE
EXITED
The Auto Learn 2me expired or the user manually exited Auto Learn mode that was
previously enabled.
SAVING FILE
A file is being saved to the USB device.
LOADING FILE
A file is being loaded from the USB device.
ACTION FAILED
The user tried to save a file to, or load from, the USB device but something went
wrong.
FLASH DRIVE NOT READY
There is either no flash drive in the USB port or the flash drive is not formaGed using
the FAT file format.
REMOTE ACTIVATION
A remote signal was received. The remote number, group and func2on is displayed.
LIMIT RESET
An end stop limit was reached before expected. Based on this limit posi2on the
controller has adjusted it’s end stop posi2on.
RUN SETUP
WIZARD FIRST
The operator cannot be used un2l the Setup Wizard is run.
ANNUALLY
♦
Many sealed lead acid baGeries do not last for more than one year. The baGery condi2on can be checked by
disconnec2ng the mains supply to the operator. Go to Quick NAV on the LCD screen and press the joys2ck to
enter the Info menu. Run the gate at least five 2mes and then read the baGery voltage (BATT. V) to make sure
the baGery is holding charge. The voltage should read 11.8V or more for a 12V baGery and 23.6V or more for a
24V baGery.
REMEMBER TO SWITCH THE POWER BACK ON!
♦
Check all guide rollers on the gate.
♦
Check all brackets and theL deterrent devices are secure.
♦
Check the motor is firmly in place and cannot move.
♦
Check the rack for any damage.
Con2nues……...
Содержание HT18/36
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...