31
……..con2nued
Add Remotes (With groups)
If the controller has more than just the original Group 0, it will prompt for the group number to which the
new remote/s must be added. ALer selec2ng the required group number follow the same steps as listed
in Add Remotes (No groups).
When Duplica2ng Group Func2ons to a Remote, it is possible to change the buGon func2on assignment
by edi2ng each remote individually. It is not, however, possible to add a func2on to that remote if the
func2on is not available to the group. When removing or adding func2ons to a group, all remotes in that
group will be affected. As an example, by removing the Trigger func2on from a group, the Trigger func-
2on on all remotes in that group will be removed.
Delete Remotes
This feature allows remotes to be deleted by selec2ng the remote’s number in the controller. Only re-
motes in the system are available for dele2on.
Edit Remotes
ALer a remote has been added to a group, it can be customized by reassigning the buGon func2ons of
the remote. It is not, however, possible to add a func2on to that remote if the func2on is not available to
the group. If a remote requires a func2on that is not in the group, the func2on can be added to the group
using the Edit Group func2on before assigning it to the buGon.
Auto Learn Remotes
This features allows for the learning of remotes onto the controller for a set period of 2me. The 2me
allowed is set up when the feature is enabled and allows for up to 30days. Two learn methods are
available:
Auto Learn
This method will accept, and learn, any EXO remote that transmits it’s code in the near vicinity. This is
useful if a controller is replaced but not all the remote holders are available to learn their remotes into
the controller memory and there is no security guard in aGendance to assist.
Buddy Learn (this is the recommended method)
This method is similar to the Auto Learn method but, in order for a remote to be learned, it is necessary
for a buGon of a remote already in the system to be pressed first and then the new remote’s buGon to be
pressed within 10 seconds. This is a more secure way of programming the controller and is ideally suited
for a complex with a security guard in aGendance. It is far less likely that unknown remotes are acci-
dentally programmed on to the controller.
Edit Group
The TRITEK uses a grouping system for managing remote users. This provides a level of security and con-
trol if the gate is used by various groups (users). Groups such as the homeowners; domes2c worker,
garden service, pool service, security guards and more can be created in addi2on to the master group
(Group 0), with 15 groups available.
Access through the gate by each group can be independently controlled and access to the main menu by
these groups can be locked, while the remotes belonging to the master group (Group 0) have the ability
to access the main menu at all 2mes (see Lock Main Menu).
Each group can be individually customized. For instance, a group created for a domes2c worker may only
allow the gate to be opened using pedestrian entry, on certain days and during certain 2mes while a
garden service group will allow the gate to open fully, on one specific day and for a limited 2me.
In each group various func2ons can be assigned to each of the 16 available func2on slots. These func-
2ons directly correspond to the 15 “buGons” of the EXO Remote. Example, if func2on 1 of a group is set
to Trigger then buGon 1 of a remote programmed to this group will be the Trigger buGon. If func2on 2 of
the group is set to Light Trigger then buGon 2 of all the remotes belonging to this group will ac2vate the
light.
Func2on 16 does not match a remote buGon configura2on but can be individually selected by using the
edit remotes func2on. Therefore, some remotes in a group can have a special addi2onal control such as
placing the gate in lockout mode, preven2ng it from closing. By default, any remote programmed to a
group will not have access to func2on 16 and needs to be specially configured to use this func2on.
It may be temporarily required for all the remotes in a group to be barred from access, for example,
when a driveway is being tarred. The Trigger func2on in the group can temporarily be changed to Pedes-
trian Trigger so that the users in that group now only have pedestrian access.
Unassigned func2ons in a group (No Func2on) means that that buGon on the remotes will have no func-
2on assigned to it. The owner of the remote can therefore assign that remote buGon to another opera-
2on such as a garage operator and will not affect the gate operator.
Con2nues……...
Содержание HT18/36
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Con2nues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...