C2-5000 Series Universal Scaler Operation Manual
23
Rotate the Menu Select knob to the right and press the knob again. This notifies
the Scaler that you are about to change the input assignment to input number
“3”. The brackets will disappear from around the input number and will appear
around the section of the display that says “Input=RGB3”. The LCD screen will
look like this:
Adjust Buttons
Button 3 = [Input=RGB3]
Press the knob again and the brackets will begin to flash indicating that the
Scaler is ready to accept the new input assignment. Rotate the Menu Select
knob to the left until the number “1” appears and then select it by pressing the
knob again. The flashing will cease and the LCD display will now look like this:
Adjust Buttons
Button 3 = [Input=RGB1]
Rotate the Menu Select knob to the right until the below depicted display
appears. You should now see the proper Video present Output Monitor.
Adjust Buttons
Exit
Pressing the Knob causes an exit of the Adjust Buttons routine. You can now
move the Menu Select knob Counter-clockwise until it’s back at the Banner
Screen.
(NOTE: Selections made in this Quick Start section only store into
temporary memory. A way to make your choices permanent will be explained
later in this manual)
7.2
Quick Start: Picture-In-Picture
Picture In Picture (PIP) has four components: Background Source, Foreground
Source, Amount of Shrinkage of the inserted image (measured as a percentage
with 100% being full screen) and, finally, the Position of the Inserted image.
For this tutorial, we’ll use two image sources: RGB1 (the background) and RGB2
(the image to be shrunk). A second PC will do nicely for the number 2 RGB
source. Although both sources in this example are RGB images, your sources
can be whatever you want. Just remember to substitute your own background
image selection for RGB1 and your PIP image selection (the image to be shrunk)
for RGB2. Before we begin, perform the Factory Reset procedure explained
above.
Содержание C2-5000 Series
Страница 1: ...C2 5000 Series Universal Scaler Operation Manual...
Страница 2: ...C2 5000 Series Universal Scaler Operation Manual 2...
Страница 4: ...C2 5000 Series Universal Scaler Operation Manual 4...
Страница 105: ...C2 5000 Series Universal Scaler Operation Manual 105 C2 5100 5200 Block Diagram...
Страница 115: ...C2 5000 Series Universal Scaler Operation Manual 115...