Single Door
5068-5502 Rev. A
CVRC-M-1D
115
J3
5
5T7
-
+
OR
ITS
CONTENTS
DISCLOSED
TO
OUTSIDE
PARTIES
WITHOUT
THE
W
RITTEN
CONSENT
OF
THE
TRANE
COMPANY
COMM
LINK
FROM
SHIELDED
PAIR
(LINES
206,
207)
1U1
J1
-
3,4
&
6
50
55
54
53
51
52
45
48
49
46
47
43
44
42
41
39
40
38
36
37
33
34
35
32
31
30
28
29
26
27
23
24
25
21
22
P3B
P3C
5T8
-
+
SEE
NOTE
4
2
1
J10
3
P10
OPTO
INPUT
START
RELAY
STOP
RELAY
PHASE
B-C
VOLTS
PHASE
C-A
VOLTS
8
6
7
1
J8
1
2
P8
J6
2
3
J4
1
2
P6
P4
5CB1
OR
5TB3
5CB1
OR
5TB3
5CB1
OR
5TB3
SEE
NOTE
2
20
18
19
17
16
14
15
13
11
12
8
9
10
7
6
L3
5
3
4
2
1
L2
L1
NOTE:
DO
NOT
GROUND
SHIELD
ON
IPC
-
STRIP
BACK
&
INSULATE
P3A
INTER-PROCESSOR COMUNICATION
5F3
5T9
1
+
5T6
-
+
BLK
2
-
J1
WHT
P1
5F2
5F1
2M
S
24
VAC
PHASE
A-B
VOLTS
4
3
STARTER
MODULE
2U1
J2
2
1
P2
1M
RES
RES
1M
2M
1A
1A
RES
2M
1M
1A
S
T3
T5
T4
S
T6
T2
T1
2.
UNLESS
OTHERWISE
NOTED,
ALL
SWITCHES
ARE
THE
INCOMING
CURRENT.
UNIT
MOUNTED
WYE-DELTA
STARTER
WIRING
BETWEEN
EXITING
STARTER
AND
CONTROL
MODULE
ARE
SHOWN.
SEE
STARTER
MANUFACTURERS
WIRING
DIAGRAM
FOR
SPECIFIC
STARTER
WIRING.
(H1
MARKING
ON
CT),
MUST
BE
FACING
TOWARDS
POLARITY
MARKING
ON
THE
CURRENT
TRANSFORMER
SHOWN
AT
25
C
(77
F),
AT
ATMOSPHERIC
SEQUENCE
OF
OPERATION.
THREE
PHASE
POWER
SUPPLY
VOLTAGE-SEE
UNIT
NAMEPLATE
RELAY
COILS
ARE
NOT
SHOWN.
CONTACTS
ARE
CONTROLLED
NORMAL
SHUTDOWN
HAS
OCCURRED.
BY
THE
LOGIC
OF
THE
MICRO-CONTROLLER.
SEE
ALL
UTILITIES
TURNED
OFF
AND
AFTER
A
PRESSURE,
AT
50%
RELATIVE
HUMIDITY,
WITH
8.
7.
6.
5.
4.
3.
NOTES:
1.
2T4
X2
X1
H2
H1
24
V.
115
V.
MOTOR
COMPRESSOR
4B1
WYE-DELTA
STARTER
P5C
P5B
P5A
215A
215B
BRN
2CT6
SUPPLIED
STARTER
IN
CUSTOMER
(LINE
11)
FROM
5T2,
5T3,
5T4
216A
213A
214A
211A
212A
216B
213B
214B
211B
212B
BRN
RED
RED
2TB2-12
BRN
RED
2CT5
2CT4
55
PHASE
C
CURRENT
PHASE
C
CURRENT
66
BLK
PHASE
B
CURRENT
PHASE
B
CURRENT
PHASE
A
CURRENT
PHASE
A
CURRENT
3
44
3
WHT
WHT
BLK
J5J5
22
BLK
WHT
11
(LINES
38
THRU
43)
TO
2TB2
211A
216A
215A
214A
213A
5T4
X1
212A
X1
SEE
NOTE
5
X1
5T3
5T2
SEE
NOTE
8
SEE
NOTE
7
2TB2-6
1M
5T1
X2
X1
H2
H1
2M
5K6
5K7
S
1A
2M
1M
2TB2-8
2TB2- 18
2TB2- 17
2TB2- 19
>600
120-30VAC
PT'S
<600
LINE
TO
30VAC
PT'S
>600
120-30VAC
PT'S
EXCEPT
FOR
6600VAC
50HZ
SEE
INSTALLATION
MANUAL
THIS
DRAWING
IS
PROPRIETARY
AND
SHALL
NOT
BE
COPIED
2M
S
1A
S
5F4
TO
1TB1-4
COND
HIGH
PRESS
SW
TRANSITION COMPLETE
START
RELAY
RELAY
TRANSITION
DEVICE
PREFIX
LOCATION
CODE
PREFIX 1 2 3 4 5
LOCATION MAIN
CONTROL
PANEL
STARTER
PANEL
PURGE UNIT
MOUNTED
DEVICE
PROVIDED
BY
OTHERS
DASHED
LINES
INDICATE
WIRING
BY
OTHERS
FOR
REMOTE
Y-D
STARTERS
RATED
GREATER
THAN
935
RLA,
SEE
STARTER
MANUFACTURERS
WIRING
DIAGRAM
FOR
SPECIFIC
CURRENT
TRANSFORMER
WIRING.
2TB2-11
2TB2-14
2TB2-13
2TB2-16
2TB2-15
30A
5K6
5K7
2M
AUX
2TB2-5
2TB2-7
5K6
UNIT
TERMINALS
ARE
NOT
DESIGNED
USE
COPPER
CONDUCTORS
ONLY!
TO
ACCEPT
OTHER
TYPES
OF
CONDUCTORS.
FAILURE
TO
DO
SO
MAY
CAUSE
DAMAGE
TO
THE
EQUIPMENT.
BLESSURES
CORPORELLES
SEVERES
L'ENTRETIEN
PEUT
ENTRAINER
DES
ELECTRIQUE
AVANT
D'EFFECTUER
FAUTE
DE
DECONNECTER
LA
SOURCE
AVANT
D'EFFECTUER
L'ENTRETIEN.
DISJONCTEURS
SITUES
A
DISTANCE
OU
LA
MORT.
HAZARDOUS
VOLTAGE!
VOLTAGE
HASARDEUX!
ELECTRIQUES
INCLUANT
LES
DECONNECTEZ
TOUTES
LES
SOURCES
SEVERE
PERSONAL
INJURY
OR
DEATH.
BEFORE
SERVICING
CAN
CAUSE
FAILURE
TO
DISCONNECT
POWER
BEFORE
SERVICING.
INCLUDING
REMOTE
DISCONNECTS
DISCONNECT
ALL
ELECTRIC
POWER
115