TERM DEFINITION
Btu
See British Thermal Unit.
Btu Factor
A numerical representation of the heating value of natural gas which may be
calculated or presented to indicate varying relationships (e.g., the number of
Btu contained in one standard cubic foot or the number of MMBtu contained in
one Mcf of gas. The factor for a given relationship will vary depending upon
whether the gas is “dry” or “saturated”.
Btu Method
A method of allocating costs between different operations or between different
products based upon the heat content of products produced in the various
operations or of the various produced products.
Btu per Cubic Foot
A measure of the heat available or released when one cubic foot of gas is
burned.
Btu, Dry
Heating value contained in cubic foot of natural gas measured and calculated
free of moisture content. Contractually, dry may be defined as less than or
equal to seven pounds of water per Mcf.
Btu, Saturated
The number of Btu’s contained in a cubic foot of natural gas fully saturated with
water under actual delivery pressure, temperature and gravity conditions. See
BTU, DRY.
Btu/CV
Used to express the heating content of gas. See British Thermal Units or
Calorific Value.
BtuMMI
Refers to the interface program or software that operates the Btu Analyzer.
Buffer
(1) A temporary storage device used to compensate for a difference in data rate
and data flow between two devices (typically a computer and a printer); also
called a spooler; (2) An amplifier to increase the drive capability, current or
distance, of an analog or digital signal.
Burst Pressure
The maximum pressure applied to a transducer sensing element or case
without causing leakage.
BUS
A data path shared by many devices (e.g., multipoint line) with one or more
conductors for transmitting signals, data, or power.
Bus Master
A type of controller with the ability to read and write to devices on the computer
bus.
Busbar
A heavy, rigid conductor used for high voltage feeders.
Butane (C4H10)
A saturated hydrocarbon (Alkane) with four carbon atoms in it’s molecule
(C
4
H
10
). A gas at atmospheric pressure and normal temperature, but easily
liquefied by pressure. Generally stored and delivered in liquefied form and used
as a fuel in gaseous form, obtained by processing natural gas as produced and
also from a process in petroleum refining. Contains approximately 3,260 Btu
per cubic foot.
Butane, Normal
see Normal Butane.
Butylene (C4H8)
A saturated hydrocarbon (Alkane) with four carbon atoms in it’s molecule
(C
4
H
8
). A gas at room temperature and pressure, but easily liquefied by
lowering the temperature or raising the pressure. This gas is colorless, has a
distinct odor, and is highly flammable. Although not naturally present in
petroleum in high percentages, they can be produced from petrochemicals or
by catalytic cracking of petroleum.
Byte
A group of binary digits that combine to make a word. Generally 8 bits. Half
byte is called a nibble. Large computers use 16 bits and 32 bits. Also used to
denote the amount of memory required to store one byte of data.
C10H22
The molecular formula for Decane.
C1H4
The molecular formula for Methane.
C2H4
The molecular formula for Ethylene.
C2H6
The molecular formula for Ethane.
Содержание XRC6490
Страница 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Страница 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Страница 20: ...1 6 Standard Enclosure Cont 18 00 15 52 RC 6890 X 28 81 15 52 28 00 20 09 18 70 Figure 1 3 Model XRC6890 ...
Страница 24: ...1 10 XRC 195 Board Specifications Cont Figure 1 5 Complete View XRC 195 Board Continued on Next Page ...
Страница 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Страница 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 56: ...2 14 AC Charging Unit Installation Cont Figure 2 12 DC Wiring Instructions Figure 2 13 AC Wiring Instructions ...
Страница 63: ...2 21 XRC Communication Jumper Settings and Field Wiring Cont Figure 2 19 Other Field Wiring I O Connections ...
Страница 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Страница 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Страница 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...