TERM DEFINITION
DIP Switches
A bank of switches typically used in setting the hardware configuration and
base address of an option card.
Direct Current
A current that does not change in direction and is substantially constant in
value.
Direct Memory Access
A method by which information can be transferred from the computer memory
to a device on the bus without using the processor.
Discharge
The conversion of chemical energy of a cell/battery into electrical energy and
withdrawal of the electrical energy into a load.
Discharge Rate
The rate, usually expressed in amperes, at which electrical current is taken
from the cell/battery.
Discrete Manifold
Also called Tubing Manifold. Used in instances when the XFC is not mounted
directly on the Orifice, usually pipe mount or wall mount.
Distillates
The distillate or middle range of petroleum liquids produced during the
processing of crude oil. Products include diesel fuel, heating oil, kerosene and
turbine fuel for airplanes.
Distillation
The first stage in the refining process in which crude oil is heated and
unfinished petroleum products are initially separated.
Distribution
The act or process of distributing gas from the city gas or plant that portion of
utility plant used for the purpose of delivering gas from the city gate or plant to
the consumers, or to expenses relating to the operating and maintenance of
distribution plant.
Distribution Company
Gas Company which obtains the major portion of its gas operating revenues
from the operation of a retail gas distribution system, and which operates no
transmission system other than incidental connections within its own system or
to the system of another company. For purposes of A.G.A. statistics, a
distribution company obtains at least 90 percent of its gas operating revenues
from sales to ultimate customers, and classifies at least 90 percent of mains
(other than service pipe) as distribution. Compare INTEGRATED COMPANY;
TRANSMISSION COMPANY, GAS.
Dkt
Abbreviation for Decatherm, equivalent to one MMBtu.
DMM Digital
Multi-Meter.
DN
Inside diameter standard.
DOS
Disk Operating System.
DOS CCU
Refers to the DOS version of the Calibration and Collection Unit. Also known as
FS/2, hand held or Dog Bone.
DOT Matrix
A group of dots/pixels forming a character or symbol, usually five dots across
and seven dots down.
DOT/Pixel
An active element that forms a character or symbol when combined in a matrix.
Download
This refers to a Totalflow procedure in which any file(s) located on a laptop PC
or storage device, may be copied to the on-board memory of a Totalflow Host
device for purposes of restoring, configuration or repair.
Downstream
The oil industry term used to refer to all petroleum activities from the processing
of refining crude oil into petroleum products to the distribution, marketing, and
shipping of the products. Also see Upstream.
Downstream Pipeline
The pipeline receiving natural gas at a pipeline inter-connect point.
DP
See Differential Pressure.
DRAM
See Dynamic Random Access memory.
Drift
A change of a reading or a set point value over long periods due to several
factors including change in ambient temperature, time, and line voltage.
Содержание XRC6490
Страница 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Страница 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Страница 20: ...1 6 Standard Enclosure Cont 18 00 15 52 RC 6890 X 28 81 15 52 28 00 20 09 18 70 Figure 1 3 Model XRC6890 ...
Страница 24: ...1 10 XRC 195 Board Specifications Cont Figure 1 5 Complete View XRC 195 Board Continued on Next Page ...
Страница 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Страница 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 56: ...2 14 AC Charging Unit Installation Cont Figure 2 12 DC Wiring Instructions Figure 2 13 AC Wiring Instructions ...
Страница 63: ...2 21 XRC Communication Jumper Settings and Field Wiring Cont Figure 2 19 Other Field Wiring I O Connections ...
Страница 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Страница 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Страница 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...