A-145
ARRAY.REGISTER DESCRIPTION
USAGE GROUP
NAME
6.10
1 = remote changed use files
Internal Only
None
6.11
1 = pccu changed use files
Internal Only
None
6.12
Move image to use
Internal Only
None
Tube Byte Register Usage Notes:
1.
Super-Compressibility Method: 0=NX19 with FIXED FT AND FP VALUES, 1=NX19 AUTO,
2=NX19 GRAVITY CO2 & N2, 3=NX19 CO2 & N2 & C1, 11=AGA-8 Gross, 12=AGA-8 Detail
2.
Characteristics Type: This was used in “Totalflow old database” format. This does not apply to
X-series, DB2 format.
3.
Live Analysis Configuration flags: 0=USE FIXED ANALYSIS, 1=USE LIVE ANALYSIS FROM
AIU, 2=USE LIVE ANALYSIS FROM OTHER PROTOCOL, 16=USE FIXED ANALYSIS ON
ERROR. USE FIXED ANALYSIS ON ERROR may be added to selections 1 or 2.
4.
Not used in Selectable Units XFC/XRC devices. Selections made using group flow rates for
Volume, Uncorrected Volume, Mass and Energy.
5.
Aux Contact 1 & 2 select bits low byte: 1=trip contact on low charger; 2=trip contact on ACF low;
4=trip contact on ACF high; 8=trip contact on Ap low; 16=trip contact on Ap high; 32=trip contact
on remote sense; 64=auto re-open; 128=trip contact on volume set-point. These registers can
also be set from 16-bit integer registers 1.10 and 1.11.
6.
The flag is used in testing the XFC/XRC. The flag will be set to a “1” when a volume calculation
and all operations associated with it are complete. Typically a test sets the flag to “0”. Then does
something to cause a calculation. It then waits until the flag is “1” to evaluate the results of the
test.
7.
The flag is used in testing the XFC/XRC. The flag will be set to a “1” when all operations
associated a log period event are complete. Typically a test sets the flag to “0” and waits until
the flag becomes a “1”. Then the logged data would be evaluated.
8.
The flag is used in testing the XFC/XRC. The flag will be set to a “1” when all operations
associated a day period event are complete. Typically a test sets the flag to “0” and waits until
the flag becomes a “1”. Then the logged data would be evaluated.
9.
This is for internal use only. A logic 1 disables tube cold and warm start functions.
10.
When this flag is 1 no events are allowed and no parameter changes are allowed from any
protocol.
11.
When this flag is 1 no events are allowed and no parameter changes are allowed.
12.
When this bit is logic 1 and the transducer is a gage transducer pressure logging in Log and Day
records is done Gage Pressure. The log gage pressure is computed by subtracting the
barometric pressure from the average of the input pressure over the log/day period.
13.
AGA-7 Factor Select Bits –
0x01, 1 /* Use Fp */
0x02, 2 /* Use Ft */
0x04, 4 /* Use s */
0x08, 8 /* Use Faux */
0x40, 64
/* Supports switchable
characteristics, this bit not writable*/
14.
Misc Select Bits –
0x01, 1
/* RTD Installed
*/
Содержание XRC6490
Страница 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Страница 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Страница 20: ...1 6 Standard Enclosure Cont 18 00 15 52 RC 6890 X 28 81 15 52 28 00 20 09 18 70 Figure 1 3 Model XRC6890 ...
Страница 24: ...1 10 XRC 195 Board Specifications Cont Figure 1 5 Complete View XRC 195 Board Continued on Next Page ...
Страница 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Страница 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 56: ...2 14 AC Charging Unit Installation Cont Figure 2 12 DC Wiring Instructions Figure 2 13 AC Wiring Instructions ...
Страница 63: ...2 21 XRC Communication Jumper Settings and Field Wiring Cont Figure 2 19 Other Field Wiring I O Connections ...
Страница 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Страница 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Страница 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...