4-10
Replacing XRC-195 Board
The XRC-195 Board is mounted to the backside of access door. It is mounted, to the door,
on standoffs. Refer to Figure 4–1 or Figure 4–2.
The XRC-195 Board, as with any electronic board, is susceptible to
damage by static electricity or improper handling. To prevent this from
occurring, user should wear a grounding strap.
A grounding strap is a conductive device used to make connection
between the person handling the board, and a high quality ground point.
Before handling the board you must install ground strap on your body
then connect it to a grounded point. This discharges electrical static
buildup from the body to ground, preventing static from discharging to the
board.
Before removal of XRC-195 Board, be certain any data has been saved
to an external storage medium. Failure to do so could result in data loss
when XRC-195 Board is removed.
Procedures
In the following procedure, the common name for a component, its
jumper number if available (Abbreviated J) or part is followed by a
number in parentheses.
Step Procedure
1.
Before XRC-195 Board (see Figure 4–1 or Figure 4–2, Item 10)
removal, disconnect the following associated connectors in this
order.
•
If used, disconnect external charging source J17 (see
Figure
4–5
Item 21).
•
Disconnect battery pack connector J16 (Item 22).
•
Slide out to the right; the following green terminal strips from
its associated XRC-195 Board connector. DO NOT lift
connectors upward. Tape an identifier to each connector so
it will be correctly reinserted into the same Board mounting
connector during reinstallation of XRC-195 Board.
J6-COMM 2 (Item# 18)
J6-COMM 1 (Item # 17)
J8-B (Item# 16)
J8-A (Item# 15)
J20 (Item# 13)
J23 (Item# 11)
•
Disconnect PCCU Port connector J15 (Item# 25).
•
LCD Interface connector J13 (Item# 24).
•
Remove cable from J18 (Item# 23) if External I/O Modules
are installed.
Continued on Next Page
Содержание XRC6490
Страница 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Страница 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Страница 20: ...1 6 Standard Enclosure Cont 18 00 15 52 RC 6890 X 28 81 15 52 28 00 20 09 18 70 Figure 1 3 Model XRC6890 ...
Страница 24: ...1 10 XRC 195 Board Specifications Cont Figure 1 5 Complete View XRC 195 Board Continued on Next Page ...
Страница 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Страница 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 56: ...2 14 AC Charging Unit Installation Cont Figure 2 12 DC Wiring Instructions Figure 2 13 AC Wiring Instructions ...
Страница 63: ...2 21 XRC Communication Jumper Settings and Field Wiring Cont Figure 2 19 Other Field Wiring I O Connections ...
Страница 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Страница 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Страница 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...