A-70
ARRAY.REGISTER DESCRIPTION
USAGE
Note
seconds
1.6
Volume Calc period
Read/Write, seconds
1.7
Daily Record Capacity
Read/Write, number of daily records, change
to this value deletes existing database and
starts new database
1.8
Log Record Capacity
Read/Write, number of log period records,
change to this value deletes existing database
and starts new database
1.9
Event Record Capacity
Read/Write, number of event records, change
to this value deletes existing database and
starts new database
1.10
Aux Contact 1 Select Bits
Read/Write, control bits
4
1.11
Aux Contact 2 Select Bits
Read/Write, control bits
4
1.12
Return number of events
available
Write, Canadian Event Log
1.13
Therms Stream Id
Read/WriteAnalysis Stream Id
1.14
Modbus address of analyzer
Read/Write
1.15
Therms use fixed or last
good
Read/Write
1.16
Daily Record Sequence
Number
Read Only
1.17
Log Record Sequence
Number
Read Only
1.18
Event Record Sequence
Number
Read Only
1.19
DP Status Flags
Read Only
5
1.20
AP Status Flags
Read Only
6
1.21
TF Status Flags
Read Only
7
1.22
PI Status Flags
Read Only
8
1.23
Ext Status Flags
Read Only
9
Tube 16-bit Integer Register Usage Notes:
1.
Primary Element Mask: 1=Orifice Square Root
2.
Calculation Method Mask: 2=AGA-3 1985, 4=AGA-3 1992; The sum of these values (6)
indicates 2 and 4 are valid choices.
3.
Super-Compressibility Method Mask: 1=NX19 with FIXED FT AND FP VALUES, 2=NX19 AUTO,
4=NX19 GRAVITY CO2 & N2, 8=NX19 CO2 & N2 & C1, 2048=AGA8 Gross, 4096=AGA8
Detail. The sum of these values (6159) indicates all of the choices listed above are valid.
4.
Aux Contact Select Bits: 1=trip contact on low charger; 2=trip contact on Dp low; 4=trip contact
on Dp high; 8=trip contact on Ap low; 16=trip contact on Ap high; 32=trip contact on Remote
Sense; 64=auto re-open; 128=trip contact on volume set-point; 256=trip contact on tf low;
512=trip contact on tf high; 1024=trip contact on flow rate low; 2048=trip contact on flow rate
high; 16384=reverse contact logic.
5.
Dp Status Flags: 1=low limit exceeded; 2=high limit exceeded; 4=over-range; 8=zero flow;
16=back flow.
6.
Ap Status Flags: 1=low limit exceeded; 2=high limit exceeded; 4=over-range; 8=zero flow;
32768=gauge pressure device.
7.
Tf Status Flags: 1=low limit exceeded; 2=high limit exceeded; 4=over-range.
Содержание XRC6490
Страница 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Страница 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Страница 20: ...1 6 Standard Enclosure Cont 18 00 15 52 RC 6890 X 28 81 15 52 28 00 20 09 18 70 Figure 1 3 Model XRC6890 ...
Страница 24: ...1 10 XRC 195 Board Specifications Cont Figure 1 5 Complete View XRC 195 Board Continued on Next Page ...
Страница 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Страница 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 56: ...2 14 AC Charging Unit Installation Cont Figure 2 12 DC Wiring Instructions Figure 2 13 AC Wiring Instructions ...
Страница 63: ...2 21 XRC Communication Jumper Settings and Field Wiring Cont Figure 2 19 Other Field Wiring I O Connections ...
Страница 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Страница 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Страница 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...