2-51
CHAPTER 2 FINISHER UNIT BASIC OPERATION
K.
Detecting Jams
The following sensors are used to detect the presence/absence of paper and to make sure that
sheets are moved properly:
●
Inlet sensor (PI1)
●
Delivery sensor (PI3)
●
Stapling tray sensor (PI4)
●
Buffer path paper sensor (PI14)
A jam is identified with reference to the presence/absence of paper at each specific sensor at the
times programmed in the memory of the microprocessor (CPU) on the finisher controller PCB.
When the CPU identifies a jam, it suspends the finisher’s delivery operation and informs the
host machine DC controller of the presence of a jam. After the paper jam is removed, the buffer path
inlet paper sensor (PI17) checks whether or not copies are being detected in addition to the above
four sensors (inlet sensor, delivery sensor, stapling tray sensor and buffer path paper sensor). If the
sensors detect a copy when all doors are closed, the finisher unit judges that paper jams have not
completely been removed, and sends the paper jam removal signal to the host machine again.
The tray-1 paper sensor (PI11) and tray-2 paper sensor (PI12) are not used to detect jams.
PI1
PI14
PI4
PI3
Figure 2-256
Table 2-205
No.
Sensor names
PI1
Inlet sensor
PI3
Delivery sensor
PI4
Stapling tray sensor
PI14
Buffer path paper sensor
Содержание MJ-1027
Страница 1: ...SERVICE MANUAL FINISHER MJ 1027 1028 File No SME040041A0 R04102169300 TTEC Ver01_2007 09 ...
Страница 5: ...ii ...
Страница 9: ...vi ...
Страница 70: ...2 41 CHAPTER 2 FINISHER UNIT BASIC OPERATION Height sensor PS1 Paper Figure 2 240 ...
Страница 101: ...3 15 CHAPTER 3 SADDLE STITCHER UNIT BASIC OPERATION Figure 3 301 ...
Страница 104: ...3 18 CHAPTER 3 SADDLE STITCHER UNIT BASIC OPERATION 2 A3 LD Paper Path 3 sheets Figure 3 303 ...
Страница 116: ...3 30 CHAPTER 3 SADDLE STITCHER UNIT BASIC OPERATION Cam Mount Figure 3 404 ...
Страница 150: ...4 20 CHAPTER 4 MECHANICAL CONSTRUCTION 7 Remove the tension springs front 5 rear 6 Figure 4 216 Figure 4 217 5 6 ...
Страница 173: ...6 CHAPTER 6 TROUBLESHOOTING II ARRANGEMENT OF ELECTRICAL PARTS A Finisher Unit ...
Страница 235: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...