• Batteries connected in series and parallel must always have the same
state of charge. You must only use the same type of batteries in battery
banks (same capacity, same age, same manufacturer, same state of
charge) and fully charge each battery separately before connecting
together. Differences in charge levels can lead to extremely high com-
pensatory currents and overloads on the cables and plugs or within the
battery itself. In extreme cases, this could cause fire or injury.
• Use Torqeedo cables to connect batteries. Cable cross-section must be
25 mm
2
(4AWG). Make sure battery poles are clean and corrosion-free.
• Cable terminals must be secured around battery posts. Tighten firmly
by rotating attached bolts.
• Disconnect batteries when storing the boat over long periods.
4.8 Preventing damage when connecting other devices
Torqeedo recommends running the Cruise FP motors on its own batte-
ry bank. Other devices such as fish finders, lights, radio, etc. should be
powered by a separate battery and not be connected to the same battery
bank as the motor.
Connecting other devices will cause an imbalance in the charge among
batteries and risks electrolysis damage if wired improperly.
If there is no option but to power a 12 V or 24 V device from one or two
of the batteries from the motor‘s battery bank, the equipment and the
motor must share the same negative terminal of battery bank
(“common ground“). See the following figure: