82
15. WARNING AND ERROR MESSAGES
15.2 Warning
Type
Message
Description
Countermeasures
SD Card
Format failed.
An error occurred during
SD card formatting.
Check that the SD card is
inserted correctly. If the error
persists, format the card using a
PC with the SD format tool pro-
vided by the SD Association on
the web. (Download from: https:/
/www.sdcard.org/jp/downloads/
formatter_4/)
If the SD card cannot be format-
ted using this tool, the SD card
may be broken. Use another SD
card. If the second SD card can-
not be formatted, have the
instrument repaired.
SD card is not seated
Please re-seat
An SD card was not
recognized.
SD card lacks space!
Change SD card
The remaining capacity of an
SD card is lower than
required for the data to be
scanned.
Delete unnecessary data in the
SD card or insert an SD card
with sufficient capacity.
Data
selection
Failed to delete this file/
folder.
The file or the directory was
not deleted.
Check that the SD card is
inserted correctly. If the error
persists, format the card using a
PC with the SD format tool pro-
vided by the SD Association on
the web. (Download from: https:/
/www.sdcard.org/jp/downloads/
formatter_4/)
If the SD card cannot be format-
ted using this tool, the SD card
may be broken. Use another SD
card. If the second SD card can-
not be formatted, have the
instrument repaired.
This file can't open!
A file other than BMP or
JPEG is selected.
Select the BMP or JPEG file.
Tilt
Tilt Over
When the tilt sensor is set
to on, the instrument is tilted
at
±
6' or more.
At the [TILT 0 ADJUST]
setting, the screen will
display the tilt angle of
±
30''
or more.
Accurately level the instrument.
Paused by vibration!
When the tilt sensor is set
to on, if vibration is detected
during scan or photograph,
those operations are going
to pause.
And if tilt value is stable
again, those operations
restart automatically.
This message is also dis-
played when the instrument
is tilted significantly.
If the operation does not
resume, it may be because that
the vibration is still continuing or
the instrument is being tilted sig-
nificantly.
Set the tilt setting off and start
those operation.