19. WARRANTY 

 

1. 

UV sterilizers are exclusively for treatment of water/liquids which content is known. 

2. 

The manufacturer of the  UV sterilizers - the TMA company guarantees efficient operation of the 
equipment covered by this warranty card. 

3. 

In order to obtain warranty service during the warranty period it is essential to: 

 

Possess  a document confirming the purchase of the equipment (purchase invoice, receipt) 

 

Perform installation and operation of the device in accordance with the instructions found in the 

manual (included with the device). 

4. 

All defects of the product determined at any time during this Warranty shall be repaired at no additional 
charge within 14 days from the date of delivery of the defective product to the manufacturer,  based on 
this filled Warranty. In exceptional situations, this period can be extended to 21 days. 

5. 

Defective equipment/product shall be delivered 

COMPLETE

 and appropriately packaged and secured 

for transport. We reserve the right to refuse to recognize a claim for damage and components resulting 
from poor security of goods in transport. 

6. 

During the warranty period, the supplier repairs or replaces parts of the equipment, in that order, as 
appropriate, in accordance with the law, without any additional cost to the buyer. Products and parts 
replaced during warranty become the property of the manufacturer. 

7. 

In the case of unfounded warranty claims, the claimant will be charged with any costs relating to the 
services performed, e.g. transport. 

8. 

Installation and commissioning of the equipment can be made by the buyer following the instructions in 
the manual that came with this product 

9. 

Manufacturer warrants that the product shall meet all specifications of performance as stated in the 
Manual for the period of: 

 

36 months from the date of purchase covering the stainless steel chamber 

 

24 months from the date of purchase covering all electrical parts of the sterilizer 

10. 

The chamber is covered by Warranty for 36 months, as long as it is used for substance disinfection, in 
accordance with the steel corrosion resistance list, according to EN 10088-1 norm. 

11. 

The use of the product not in accordance with the EN 10088-1 norm shall result in the loss of Warranty 
for the chamber and cannot be grounds for any claims in case of chamber damage. 

12. 

The water flowing through the device cannot contain sulphur, solid substances that can be filtered or 
iron over 0.3 mg/dm3. 

13. 

No warranty is given for the chambers made from AISI 304 stainless steel in the case of:  

 

Chlorinated water with chlorine content greater than 0.3 mg/dm

3

, e.g. in swimming pools 

 

The contents of chlorides greater than 200 mg/dm3 

 

pH outside the range 6.5-9.5 

 

application for brine water above 250 mg/dm3 NaCl 

 

application to demineralized and distilled water 

 

No warranty is given for the chambers made from AISI 316 stainless steel in the case of:

 

 

Chlorinated water with chlorine content greater than 1,0 mg/dm

3

 

 

The contents of chlorides greater than 450 mg/dm3 

 

pH outside the range 6.5-9.5 

 

Application for brine water above 800 mg/dm3 NaCl

 

14. 

The purchaser shall have the right to have the product replaced if: 

 

It is determined that there is a manufacturing defect which is irreparable; or 

 

During the Warranty period there is a need of 4 repairs and even after these the exploitation of 

the product according to the instructions is impossible. 

15. 

The term ‘repair’ does not cover all the actions stipulated in the Manual (i.e. routine maintenance) which 
are to be performed by the user. 

16. 

The Warranty does not include: 

 

Damage caused by inadequate storage of the products by the purchaser 

 

Damage caused by faulty assembly or exploitation of the sterilizer 

Содержание AP-POOL-X 1

Страница 1: ...Made in Poland WATER UV STERILIZERS AP POOL X SERIES MANUAL Patent No 204935 December 2019 WATER UV STERILIZERS...

Страница 2: ...AP POOL X16 MODELS 10 5 INSTRUCTION FOR INSTALLATION AND OPERATION 11 5 1 CHAMBER ASSEMBLY 11 5 2 QUARTZ SLEEVES ASSEMBLY 13 5 3 UV LAMPS AND ELECTRICAL ENCLOSURE ASSEMBLY 14 5 4 MOUNTING TEMPERATURE...

Страница 3: ...led and grounded in accordance with this manual and the local electrical code To guard against electrical shock unplug the device every time work is to be done on it GROUNDING Operation of the device...

Страница 4: ...rated for the device New features allow continuing disinfection even without the flow of water through the chamber Sterilizers do not require control of flow and temperature of water by the user The s...

Страница 5: ...ater Sterilizer uses special low pressure UV lamp to produce UV radiation of wavelength of 254 nm and 185nm which causes photochemical reaction damaging DNA of microorganisms leading to death or steri...

Страница 6: ...CHAMBER Chamber Material Stainless Steel AISI 316 316L Finish Polished Powder coating Safety Class IP 66 Operating Pressure 3 5 bar 0 35MPa Operating Temperature Recommended 0 5 50 C Quartz Sleeve Gu...

Страница 7: ...50 kg STERILIZER CHAMBER Chamber Material Stainless Steel AISI 316 316L Finish Polished Powder coating Safety Class IP 66 Operating Pressure 3 5bar 0 35MPa Operating Temperature Recommended 0 5 50 C Q...

Страница 8: ...is used to empty the chamber from fluid The power supply system is mounted in the electrical enclosure and connected with the sterilizer by hi potential wires The enclosure houses besides the power s...

Страница 9: ...ter removing the bridge it is possible to connect remote controlled switch to the ON OFF terminals caution voltage 230V CONTACTS 1 2 CLOSED sterilizer on CONTACTS 1 2 OPEN sterilizer off BALAST ON OFF...

Страница 10: ...amp damage Alarm on Power cut off 4 5 CONNECTION OF SOLENOID VALVE IN AP POOL X2 AP POOL X16 MODELS There is possible to connect solenoid valve max 2A to the terminals 1 2 neutral on the electronic pl...

Страница 11: ...ges without appropriate support f Upstream of the intake install potable water filter minimum rating 0 1 mm recommended 0 05 mm Water shall not contain more than 0 3mg Fe and 0 1 Mn g Install cut off...

Страница 12: ...NUAL AP POOL X SERIES 12 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Vertical Forbidden Supports Horizontal Supports Supports Horizontal Horizontal For...

Страница 13: ...all not break the sleeve c Fill the chamber under full pressure and check the seal tightness ATTENTION Tightening the muffs with other tools may cause quartz sleeves breakage O RING STERILIZER CHAMBER...

Страница 14: ...ot done as required the UV lamps may break after turning on the device LAMP HOOD STRAIN RELIEF PLACE SOCKET ON LAMP END WITH FOUR PINS UV LAMP SOCKET CENTERING RING UV LAMP STRAIN RELIEF INSERT UV LAM...

Страница 15: ...d shut off valve shall be connected through terminals 1 2 Solenoid shut off valve serves the purpose of preventing unsterilized fluid entering the installation downstream of the sterilizer in the case...

Страница 16: ...isplay An intermittent sound signal UV lamp reached its end of life time HOLD 3 s PRZYTRZYMA 3 s Hold left button more than 3 seconds to silence the sound alarm max 2 times Blinking number 0 on the di...

Страница 17: ...n on the power switch while still holding the right button for more than 10 seconds f Short sound signal will confirm resetting the work time counter 8 LEGEND FOR INDICATOR LIGHT ON ENCLOSURE Lighted...

Страница 18: ...led i Water not fit for consumption may require treatment i e deironing softening or filtering If any doubt please contact your dealer j In case of high turbidity and waste water the choice of equipme...

Страница 19: ...breaker C10 AP POOL X6 Circuit breaker C13 AP POOL X8 Circuit breaker C16 AP POOL X10 Circuit breaker C20 AP POOL X12 Circuit breaker C16 AP POOL X16 Circuit breaker C16 10 INSTRUCTION FOR REPLACEMEN...

Страница 20: ...uartz sleeve g Slide the sleeve out of guides and nipple of the sterilizer h Every time the UV lamp is replaced when it is necessary to clean the quartz sleeve use common glass cleaners and then insid...

Страница 21: ...s in item 1 1 Procedures in the event of failure in multi radiator devices Description The alarm indication LED RED on one of the UV radiators lights up in the control cabinet and there is constant au...

Страница 22: ...is NOT working Alarm system signals failure red LED Damaged electrical ballasts Alarm system signals proper work green LED Damaged electrical ballasts and or damaged alarm system UV lamp is working A...

Страница 23: ...mm DN D mm a mm b mm c mm APP X1 276 220 1700 1470 72 50 3 220 325 250 120 APP X2 320 220 1735 1456 110 DN100 220 400 400 200 APP X3 375 250 1735 1430 125 DN125 256 400 600 250 APP X4 420 340 1740 13...

Страница 24: ...01 2 pcs 4 pcs 6 pcs 8 pcs 10 pcs 12 pcs 16 pcs 20 pcs 24 pcs 32 pcs 4 O RING MUFF 01 04 01 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 8 pcs 10 pcs 12 pcs 16 pcs 5 WASHER 01 05 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs...

Страница 25: ...TMA MANUAL AP POOL X SERIES 25 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 16 HYGIENIC CERTIFICATE...

Страница 26: ...TMA MANUAL AP POOL X SERIES 26 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 17 DECLARATION OF CONFORMITY...

Страница 27: ...TMA MANUAL AP POOL X SERIES 27 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 18 GRAFICAL MOUNTING INSTRUCTION...

Страница 28: ...TMA MANUAL AP POOL X SERIES 28 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Assemble of AP POOL X sterilizer...

Страница 29: ...TMA MANUAL AP POOL X SERIES 29 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Assemble of UV lamps in AP POOL X chamber 2 3 4 5 1...

Страница 30: ...all meet all specifications of performance as stated in the Manual for the period of 36 months from the date of purchase covering the stainless steel chamber 24 months from the date of purchase coveri...

Страница 31: ...e is used for purposes and in a manner inconsistent with the recommendations applicable in the manual data sheet warranty card Damage caused by unforeseen natural phenomena i e floods frost storms hur...

Страница 32: ...POOL X SERIES 32 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Warranty and post warranty repairs Receive date Type of failure and repair procedure End d...

Отзывы: