12. TROUBLESHOOTING
Lp.
Problem
Cause
Action
1
Burned out UV Lamp
Water inside the quartz
sleeve - . short circuit
–
open circuit on circuit
breaker
Muff not tightened
sufficiently.
Worn out O-ring.
Take quartz sleeve out, dry interior,
change O-ring, and assemble back.
Tighten muff. If device does not
work
– electronic ballast damaged –
replace
– contact dealer
2
Burned out UV lamp
End of lamp life caused by
number of working hours and
number of on-off cycles.
Replace UV lamp.
3
Operation of the device
causes the circuit breakers
or differential switches to
be disconnected
- There was a short circuit in
the electrical system - the
water got into the quartz
sleeve/UV radiator - badly
tightened muff
Disconnect the unit from the power
supply; check the condition of the UV
radiators and the quartz tubes.
In case of getting water into the
quartz tubes proceed as in item 1.
1) Procedures in the event of failure in multi-radiator devices
Description:
The alarm indication LED /RED/ on one of the UV radiators lights up in the control
cabinet and there is constant audible alarm.
Cause:
There is a malfunction or burnout of the UV radiator.
The alarm system or ballasts are damaged.
Procedure:
a. Disconnect the device from the power supply
b. If the device is warmed up wait for it to cool down.
c. Disconnect all UV radiator that work properly (remove the plastic socket from the
UV radiator).
d. Put the lamp hoods on all muffs.
LAMP HOODS MUST BE IMPOSED ON ALL MUFFES TO PROTECT THE USER FROM UV RADIATION
e. Reboot the unit and check the UV radiator and alarm system (in this case, the
alarm system should indicate failure of all sections that are not connected to the
UV radiators). Wait 2-3 minutes for UV radiator to warm up.
UV lamp is
NOT
working
Alarm system signals
failure
– red LED
Burned out UV lamp
Alarm system signals
proper work
– green
LED
Burned out UV lamp and/or
damaged alarm system
UV lamp is
working
Alarm system signals
failure
– red LED
Damaged alarm system
Alarm system signals
proper work
– green
LED
Everything works properly