TMA
MANUAL – AP-POOL-X SERIES
10
TMA
|
B
iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413
4.4.
LEADING OUT THE ALARM SIGNAL IN AP-POOL-X2-AP-POOL-X16 MODELS
Connect the alarm signal wires to the terminals 1 & 2 /neutral/ on the terminal blocks in
electrical enclosure /in the right bottom corner/.
The contacts 1 and 2 operate with a preset delay of about 2-3 minutes - this is the time to
reach the full efficiency of the device. During this period, terminals 1 and 2 are open.
After 2-3 minutes, the device operates as follows:
CONTACTS 1-2 CLOSED
- sterilizer working properly
CONTACTS 1-2 OPEN
- UV lamp damage
- Alarm on
- Power cut off
4.5. CONNECTION OF SOLENOID VALVE IN AP-POOL-X2-AP-POOL-X16
MODELS
There is possible to connect solenoid valve [max. 2A] to the terminals 1 & 2 /neutral/ on the
electronic plate in electrical enclosure.
The contacts 1 and 2 operate with a preset delay of about 2-3 minutes - this is the time to
reach the full efficiency of the device. During this period, terminals 1 and 2 are open.
After 2-3 minutes, the device operates as follows:
CONTACTS 1-2 CLOSED
- sterilizer working properly
CONTACTS 1-2 OPEN
- UV lamp damage
- Alarm on
- Power cut off
4.6. REMOTE-CONTROLLED ON/OFF SWITCH IN AP-POOL-X2-AP-POOL-X16
MODELS
After removing the bridge, it is possible to connect remote-controlled switch to the terminals 3
& 4 /
caution: voltage 230V!, I=0,2A
/.
CONTACTS 1-2 CLOSED
- sterilizer on
CONTACTS 1-2 OPEN
- sterilizer off