5.3. UV LAMPS AND ELECTRICAL ENCLOSURE ASSEMBLY
(GRAPHICAL INSTRUCTIONS AT PAGE 27-29)
a) Mount electrical enclosure on wall, at least 60 cm from the floor.
b) Place the socket on the end of UV lamp with four pins. Gently slide the fully connected
lamp into the quartz sleeve.
!!! CAUTION !!!
MOUNT UV LAMPS IN PROTECTIVE, PREFERABLY COTTON GLOVES.
If not done as required, the UV lamps may break after turning on the device.
LAMP HOOD
STRAIN RELIEF
PLACE SOCKET ON
LAMP END WITH FOUR
PINS
UV LAMP
SOCKET
CENTERING RING
UV LAMP
STRAIN RELIEF
INSERT UV LAMP
INTO QUARTZ
SLEEVE
SOCKET
LAMP HOOD
PLACE LAMP HOOD
OVER MUFF
WASHER
O-RING
STERILIZER
CHAMBER
QUARTZ SLEEVE
MUFF
O-RING ON MUFF
CENTERING RING
c) Place lamp hood over muff.
d) Plug in to mains 230V, 50 Hz, in the electrical enclosure, according to the labels.
e) Turn device on by using switch on the side or front of electrical enclosure. Green
indicator light goes on when device is connected to power and powered up.
f) Replace UV lamps after its end of life time.