MANUAL – AP-POOL-X SERIES
11
TMA
|
B
iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413
AP-POOL-X2 - Diagram for solenoid valve, alarm signal and outside connection of the device.
5. INSTRUCTION FOR INSTALLATION AND OPERATION
5.1.
CHAMBER ASSEMBLY
a) Device assembles in horizontal position. Temperature range for installation is from 0.1
to 35
o
C. DO NOT ALLOW THE CHAMBER TO FREEZE.
b) Correct assembly shall prevent the creation of air gap in the chamber.
c) By-pass installation is recommended.
d) Assembly cannot cause strain on the nipples.
e) It is forbidden to mount the sterilizer on flanges without appropriate support.
f)
Upstream of the intake install potable water filter, minimum rating 0.1 mm,
recommended 0.05 mm
.
Water shall not contain more than 0.3mg Fe and 0.1 Mn.
g) Install cut-off valves on both sides.
UV STERILIZER
ELECTRICAL ENCLOSURE
OUTLET
SOLENOID VALVE
SOLENOID VALVE
CORD
REMOVE DOORS OF THE
ELECTRICAL ENCLOSURE
POWER LINE
terminal block in electrical enclosure, after removing
the jumper cable, connect remote switching on/off of the
sterilizer:
Closed circuit
- sterilizer on
Open circuit
- sterilizer off
To the terminals 1 & 2 /neutral/ on the terminal
blocks in electrical enclosure/ solenoid valve type
NZ (normally closed) max. 2a can be connected.
Circuit closed
- sterilizer working
properly
Circuit open
- UV lamp damage
- Alarm on
- Power cut off