TMA
MANUAL – AP-POOL-X SERIES
20
TMA
|
B
iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413
ATTENTION
!
In model AP-POOL-X sterilizers UV lamps must have special centering ring at both ends.
When the UV lamps are shipped from the manufacturer, the centering rings are provided with
every lamp.
11. REPLACEMENT AND CLEARING OF THE QUARTZ SLEEVE
(WARNING: VERY BRITTLE)
(GRAPHICAL INSTRUCTIONS AT PAGE 28)
In order to replace quartz sleeve one shall:
a) Disconnect the power supply,
b) Cut off the liquid flow through the chamber,
c) Allow for lamp to cool down from operating temperature,
d) Remove UV lamp according to p. 10. /Instruction for replacement of UV lamp/,
e) Unscrew the steel muff using special spanner,
f) Take off the washer and O-ring from the quartz sleeve,
g) Slide the sleeve out of guides and nipple of the sterilizer,
h) Every time the UV lamp is replaced, when it is necessary to clean the quartz sleeve
use common glass cleaners and then inside of the sleeve should be thoroughly dried
so that no liquid is left there,
ATTENTION!
SLEEVE IS MADE OF PURE QUARTZ
– VERY BRITTLE
ATTENTION!
AT THE TIME OF REPLACEMENT OR CLEARING OF THE QUARTZ SLEEVE, THE O-RING MUST BE REPLACED
i) Slide carefully the new or cleaned quartz sleeve into the chamber of the sterilizer,
j) Place
new O-ring
over the sleeve, then place the washer,
k)
Tighten the muff over the O-ring and washer with the provided tool. Check the proper placement of the
O-ring, it should be lodged into the
conical groove in the nipple of the sterilizer
,
l) Open gradually the cut-off valves, flood the chamber, and check the seal around the
sleeve. If it springs a leak, tighten the muff till tight seal is obtained,
m) Place the UV lamp according with p. 10 of this Manual.