background image

 

TMA 

MANUAL – AP-POOL-X SERIES  

8

 

 

TMA

 | 

B

iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413

 

 
 

Standard features: 

  Sterilizer chamber made from stainless steel (AISI 316/316L), 

  Electrical enclosure, with control system,  

  Set of quartz sleeves  

  Set of UV lamps 

  Set of O-rings + backup set of O-rings 

  Terminals for  connecting  electromagnetic  valve  shutting  off flow  in  case  of  power 

or lamp failure 

 

Optional Accessories: 

-

 

UV intensity sensor

 

-

 

Sterilizer supports

 

 
 

4. TECHNICAL DESCRIPTION 

 

 

Sterilizer’s  chamber  is  totally  made  from  stainless  steel.      Quartz  sleeves  with  UV 

lamps are mounted in the chamber.  

When mounted vertically, the inlet should be located in the bottom part of the chamber 

and the outlet in the upper part. When mounted horizontally, the arrangement is optional. At 
the bottom of the chamber the drain plug is located, which is used to empty the chamber from 
fluid. The power supply system is mounted in the electrical enclosure and connected with the 
sterilizer by hi-potential wires. The enclosure houses, besides the power supply, is equipped 
lamp  working  hours  counter,  the  audible  and  optical  alarm,  and  indicating  lights  with  the 
terminals for electromagnetic shutoff valve in case of lamp or power failure. 
Power supply is 220-

230V ± 10%, 50-60 Hz (or 3 x 220-230V 50/60Hz).  

The device has anti-shock protection by earth terminal. 
Sight glass muff enables indication of working condition of the UV lamps.

  

 
 

4.1. 

LEADING OUT THE ALARM SIGNAL IN AP-POOL-X1 MODEL

 

 

Connect  alarm  signal  wires  to  the  terminals  1  &  2  on  electronic  plate  /neutral 

–  without 

voltage/. 
The  contacts  1  and  2 operate  with  a  preset  delay  of  about  2-3 minutes  -  this  is  the  time  to 
reach the full efficiency of the device. During this period, terminals 1 and 2 are open.  
After 2-3 minutes, the device operates as follows: 
 

 

CONTACTS 1-2 CLOSED

 

- sterilizer working properly 

 

CONTACTS 1-2 OPEN

 

- UV lamp damage 
- Alarm on  
- Power cut off 

 
 
 
 
 
 
 

 

Содержание AP-POOL-X 1

Страница 1: ...Made in Poland WATER UV STERILIZERS AP POOL X SERIES MANUAL Patent No 204935 December 2019 WATER UV STERILIZERS...

Страница 2: ...AP POOL X16 MODELS 10 5 INSTRUCTION FOR INSTALLATION AND OPERATION 11 5 1 CHAMBER ASSEMBLY 11 5 2 QUARTZ SLEEVES ASSEMBLY 13 5 3 UV LAMPS AND ELECTRICAL ENCLOSURE ASSEMBLY 14 5 4 MOUNTING TEMPERATURE...

Страница 3: ...led and grounded in accordance with this manual and the local electrical code To guard against electrical shock unplug the device every time work is to be done on it GROUNDING Operation of the device...

Страница 4: ...rated for the device New features allow continuing disinfection even without the flow of water through the chamber Sterilizers do not require control of flow and temperature of water by the user The s...

Страница 5: ...ater Sterilizer uses special low pressure UV lamp to produce UV radiation of wavelength of 254 nm and 185nm which causes photochemical reaction damaging DNA of microorganisms leading to death or steri...

Страница 6: ...CHAMBER Chamber Material Stainless Steel AISI 316 316L Finish Polished Powder coating Safety Class IP 66 Operating Pressure 3 5 bar 0 35MPa Operating Temperature Recommended 0 5 50 C Quartz Sleeve Gu...

Страница 7: ...50 kg STERILIZER CHAMBER Chamber Material Stainless Steel AISI 316 316L Finish Polished Powder coating Safety Class IP 66 Operating Pressure 3 5bar 0 35MPa Operating Temperature Recommended 0 5 50 C Q...

Страница 8: ...is used to empty the chamber from fluid The power supply system is mounted in the electrical enclosure and connected with the sterilizer by hi potential wires The enclosure houses besides the power s...

Страница 9: ...ter removing the bridge it is possible to connect remote controlled switch to the ON OFF terminals caution voltage 230V CONTACTS 1 2 CLOSED sterilizer on CONTACTS 1 2 OPEN sterilizer off BALAST ON OFF...

Страница 10: ...amp damage Alarm on Power cut off 4 5 CONNECTION OF SOLENOID VALVE IN AP POOL X2 AP POOL X16 MODELS There is possible to connect solenoid valve max 2A to the terminals 1 2 neutral on the electronic pl...

Страница 11: ...ges without appropriate support f Upstream of the intake install potable water filter minimum rating 0 1 mm recommended 0 05 mm Water shall not contain more than 0 3mg Fe and 0 1 Mn g Install cut off...

Страница 12: ...NUAL AP POOL X SERIES 12 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Vertical Forbidden Supports Horizontal Supports Supports Horizontal Horizontal For...

Страница 13: ...all not break the sleeve c Fill the chamber under full pressure and check the seal tightness ATTENTION Tightening the muffs with other tools may cause quartz sleeves breakage O RING STERILIZER CHAMBER...

Страница 14: ...ot done as required the UV lamps may break after turning on the device LAMP HOOD STRAIN RELIEF PLACE SOCKET ON LAMP END WITH FOUR PINS UV LAMP SOCKET CENTERING RING UV LAMP STRAIN RELIEF INSERT UV LAM...

Страница 15: ...d shut off valve shall be connected through terminals 1 2 Solenoid shut off valve serves the purpose of preventing unsterilized fluid entering the installation downstream of the sterilizer in the case...

Страница 16: ...isplay An intermittent sound signal UV lamp reached its end of life time HOLD 3 s PRZYTRZYMA 3 s Hold left button more than 3 seconds to silence the sound alarm max 2 times Blinking number 0 on the di...

Страница 17: ...n on the power switch while still holding the right button for more than 10 seconds f Short sound signal will confirm resetting the work time counter 8 LEGEND FOR INDICATOR LIGHT ON ENCLOSURE Lighted...

Страница 18: ...led i Water not fit for consumption may require treatment i e deironing softening or filtering If any doubt please contact your dealer j In case of high turbidity and waste water the choice of equipme...

Страница 19: ...breaker C10 AP POOL X6 Circuit breaker C13 AP POOL X8 Circuit breaker C16 AP POOL X10 Circuit breaker C20 AP POOL X12 Circuit breaker C16 AP POOL X16 Circuit breaker C16 10 INSTRUCTION FOR REPLACEMEN...

Страница 20: ...uartz sleeve g Slide the sleeve out of guides and nipple of the sterilizer h Every time the UV lamp is replaced when it is necessary to clean the quartz sleeve use common glass cleaners and then insid...

Страница 21: ...s in item 1 1 Procedures in the event of failure in multi radiator devices Description The alarm indication LED RED on one of the UV radiators lights up in the control cabinet and there is constant au...

Страница 22: ...is NOT working Alarm system signals failure red LED Damaged electrical ballasts Alarm system signals proper work green LED Damaged electrical ballasts and or damaged alarm system UV lamp is working A...

Страница 23: ...mm DN D mm a mm b mm c mm APP X1 276 220 1700 1470 72 50 3 220 325 250 120 APP X2 320 220 1735 1456 110 DN100 220 400 400 200 APP X3 375 250 1735 1430 125 DN125 256 400 600 250 APP X4 420 340 1740 13...

Страница 24: ...01 2 pcs 4 pcs 6 pcs 8 pcs 10 pcs 12 pcs 16 pcs 20 pcs 24 pcs 32 pcs 4 O RING MUFF 01 04 01 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 8 pcs 10 pcs 12 pcs 16 pcs 5 WASHER 01 05 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs...

Страница 25: ...TMA MANUAL AP POOL X SERIES 25 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 16 HYGIENIC CERTIFICATE...

Страница 26: ...TMA MANUAL AP POOL X SERIES 26 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 17 DECLARATION OF CONFORMITY...

Страница 27: ...TMA MANUAL AP POOL X SERIES 27 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 18 GRAFICAL MOUNTING INSTRUCTION...

Страница 28: ...TMA MANUAL AP POOL X SERIES 28 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Assemble of AP POOL X sterilizer...

Страница 29: ...TMA MANUAL AP POOL X SERIES 29 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Assemble of UV lamps in AP POOL X chamber 2 3 4 5 1...

Страница 30: ...all meet all specifications of performance as stated in the Manual for the period of 36 months from the date of purchase covering the stainless steel chamber 24 months from the date of purchase coveri...

Страница 31: ...e is used for purposes and in a manner inconsistent with the recommendations applicable in the manual data sheet warranty card Damage caused by unforeseen natural phenomena i e floods frost storms hur...

Страница 32: ...POOL X SERIES 32 TMA Bia ostoczek 26 gm Zab ud w 15 592 Bia ystok Poland Tel 48 857431246 VAT EU PL5420008413 Warranty and post warranty repairs Receive date Type of failure and repair procedure End d...

Отзывы: