TMA
MANUAL – AP-POOL-X SERIES
9
TMA
|
B
iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413
4.2.
CONNECTION OF SOLENOID VALVE IN AP-POOL-X1 MODEL
There is possible to connect solenoid valve [max. 2A] to the terminals 1 & 2 /neutral/ on the
electronic plate in electrical enclosure.
The contacts 1 and 2 operate with a preset delay of about 2-3 minutes - this is the time to
reach the full efficiency of the device. During this period, terminals 1 and 2 are open.
After 2-3 minutes, the device operates as follows:
CONTACTS 1-2 CLOSED
- sterilizer working properly
CONTACTS 1-2 OPEN
- UV lamp damage
- Alarm on
- Power cut off
4.3.
REMOTE-CONTROLLED ON/OFF SWITCH IN AP-POOL-X1 MODEL
After removing the bridge, it is possible to connect remote-controlled switch to the ON/OFF
terminals /
caution: voltage 230V!
/.
CONTACTS 1-2 CLOSED
- sterilizer on
CONTACTS 1-2 OPEN
- sterilizer off
BALAST ON/OFF SWITCH N L ~230V
1
1 2
2
1
UV STERILIZER
OUTLET
SOLENOID VALVE
POWER LINE
To the terminals ON/OFF /
caution: voltage 230V!
/ on
electronic plate in electrical enclosure, after removing
the jumper cable, connect remote switching on/off of
the sterilizer:
Closed circuit
- sterilizer on
Open circuit
- sterilizer off
ELECTRONIC PLATE
IN AM1 MODELS
To the terminals 1 & 2 /neutral/ on the electronic
plate in electrical enclosure/ solenoid valve type
NZ (normally closed) max. 2a can be connected.
Circuit closed
- sterilizer working
properly
Circuit open
- UV lamp damage
- Alarm on
- Power cut off
ELECTRICAL ENCLOSURE
POWER LINE
FUSE
AP-POOL-X1
– Diagram for solenoid valve, alarm signal and outside connection of the device.