t) Using faulty or post end of life UV lamps / operating time above their durability period /
can lead to damage to electronic ballast located in the electrical enclosure.
When
replacing the UV lamp, protective gloves should be worn.
u) Excessive humidity and water inside the quartz sleeve can cause damage to the
power supply of the UV lamp.
v) The leakage current going into grounding is 1,5 mA for each UV lamp.
w) Fans in control cabinets should be replaced every 50 000h.
x) In control cabinets there are mounted protection devices as below:
Sterilizer type
Protection device
AP-POOL-X1
Fuse 2A
AP-POOL-X2
Circuit breaker C6
AP-POOL-X3
Circuit breaker C6
AP-POOL-X4
Circuit breaker C10
AP-POOL-X5
Circuit breaker C10
AP-POOL-X6
Circuit breaker C13
AP-POOL-X8
Circuit breaker C16
AP-POOL-X10
Circuit breaker C20
AP-POOL-X12
Circuit breaker C16
AP-POOL-X16
Circuit breaker C16
10. INSTRUCTION FOR REPLACEMENT OF UV LAMP
(GRAPHICAL INSTRUCTIONS AT PAGE 28-29)
ATTENTION
!
1. Always wear protective gloves (preferably cotton) when replacing / installing the UV lamp.
Do not touch the UV lamp with your bare hand.
2. When installing the UV lamp, hold the lamp by the glass.
3. Holding or inserting the UV lamp by the lampholder may damage it.
In order to replace the UV lamp one shall:
a) Disconnect from power supply /neutral and life/,
Replacing the radiator does not require shutting off the water flow through the chamber.
b) Put on protective gloves, preferably made of cotton,
c) Take off plastic hood,
d) Slide out the UV lamp from the quartz sleeve,
DO NOT UNSREW THE STEEL MUFF!
e) Remove sockets from connectors of the UV Lamp,
f) Remove old UV lamp from the quartz sleeve,
g) Carefully place the new UV lamp in the sleeve,
h) Reverse the remaining steps.