TMA
MANUAL – AP-POOL-X SERIES
15
TMA
|
B
iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413
ATTENTION!
1.
Any fault of UV lamp, including burn out, is signalized by lighting up of red indicator lamp
and tripping of audible alarm.
2.
Incidental powering of the electrical enclosure without connected UV lamps may cause
damage to electronic ballast driving UV lamps.
ATTENTION!
In case of installing solenoid shut-off valve ( terminals 1 & 2) upstream /or
downstream/ of the sterilizer, tripping alarm or power interruption causes immediate shutting
off of fluid flow to the chamber of the sterilizer
/ Section 4.3-4.6/.
Terminals 1 & 2 are neutral.
Power to solenoid shut-off valve shall be connected through terminals 1 & 2.
Solenoid shut-off valve serves the purpose of preventing unsterilized fluid entering the
installation downstream of the sterilizer in the case of power interruption or lamp failure.
5.4. MOUNTING TEMPERATURE SENSOR (MODELS AP-POOL-X2-AP-POOL-
X16)
UV STERILIZER
POWER LINE
UV LAMPS
SCREW PLASTIC
GLAND INTO THE
STERILIZER
TEMPERATURE
SENSOR
ELECTRICAL ENCLOSURE
a) Choose the temperature sensor cord
(ended with strain relief PG11).
b) Loosen the cable gland
c) Install the strain relief into the hole at
the center of sterilizer (between the UV
lamps mountings)
d) Move the wire to the end of the hole.
e) Tighten the strain relief.
ATTENTION!
Improper mounting of temperature sensor
can cause a short circuit, resulting in failure
of whole device
Turning
off
radiators
occurs
at
a
temperature of a
pprox. 85°C. Resuming at
approx. 65°C