TMA
MANUAL – AP-POOL-X SERIES
4
TMA
|
B
iałostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT EU PL5420008413
1. GENERAL INFORMATION
Thank you and congratulations on your purchase of TMA manufactured UV
sterilization product. Sterilizers made by TMA are made from highest quality stainless steel.
The thickness of the chamber wall guarantees high factor of safety in operation. All the raw
materials and components are of best quality and were processed or manufactured in the EU
countries. Plastics used in production of the lamp hoods withstand 110
C working
temperatures. Devices completed successfully 30 Atm pressure trials.
AP-POOL-X series sterilizers are equipped with electronic control system and alarm.
Apart from that they are provided with:
Audible UV Lamp Fault Alarm
Optical UV Lamp Fault Alarm
Total Work Time Counter
Number of switches counter
In AP-POOL-X models we introduced additional guides for the quartz sleeves easing
the assembly and disassembly. This solution allows the same ease of assembly for device
working horizontally or vertically. This guide prevents the quartz sleeve from breaking during
the routine maintenance. The turbulent flow induced by the guide increases the efficaciency
of disinfection. During the first 100 hours of operation the efficiency of disinfection is greater
by 15% from the rated for the device.
New features allow continuing disinfection even without the flow of water through the
chamber. Sterilizers do not require control of flow and temperature of water by the user.
The
ster
ilizer without flow could heat up to a maximal temperature of 85 ° C, after that it will turn
off radiators. Return to work will take place at a temperature of approx. 65 ° C.
The design of the chamber contributes to lower incidence of sediment from calcium
and magnesium on the surface of the quartz sleeve.
The AP-POOL-X models are equipped with more durable amalgamate lamps - up to
16,000 hours of service. The plastic lamp hood has a secondary function as a sight glass.
This innovative solution of the use of transparent to visible light lamp hoods allows optical
indication of the state of the lamp.
We hold high hopes that the implementations of these innovative solutions fulfill your
expectations for new and more efficient products from TMA.
MANUFACTURER RESERVES THE RIGHT TO CHANGE THE CONSTRUCTION WITHOUT NOTICE
The device delivered to you is disassembled and shall be protected from severe shocks
and drops, as the quartz sleeve and lamps are brittle and fragile. The sterilizer shall be
exclusively transported in horizontal position. The manufacturer is not responsible for
damage arising from the conditions of transport.
Before installation and operation one shall read the instructions and implement the
precautions listed.
Noncompliance with these precautions is grounds for releasing the manufacturer from
warranty obligations.