background image

The Rainbow Quantum Micro-Injector represents 
a new era in tree injection design and battery-
powered performance for the care of urban 
ecosystems. The Quantum protects trees from 
deadly pests while doing minimal harm, using a 
variable pressure system and plug-less tips. It is 
lightweight, accurate, and able to work all day.

www.RainbowEcoscience.com/quantum

Digital Download of this Manual Available at:

Manual

Ordering & Tech Support: 

877-272-6747 

www.RainbowEcoscience.com

Or scan here for the "How To" video

Содержание Quantum

Страница 1: ...Quantum protects trees from deadly pests while doing minimal harm using a variable pressure system and plug less tips It is lightweight accurate and able to work all day www RainbowEcoscience com quan...

Страница 2: ...ng The Device Calibrate Injecting With The Device Drilling Injection Sites Injecting Injections Wrap Up Storing Of The Device Quantum General Care Storage Quantum Troubleshooting Quantum Repair Instru...

Страница 3: ...Carrying Strap 1 x Reservoir Labels 1 x 10ml Measuring Cylinder Electric Drill Dewalt For Optimal Battery Swapping DBH Tape Proper PPE Safety Glasses NOTE polarized glasses may help with screen legibi...

Страница 4: ...traight push to connect fitting on the side of the device 3 Set Up Your New Device 2 Ordering Tech Support 877 272 6747 www RainbowEcoscience com II Starting The Device 1 Insert fully charged battery...

Страница 5: ...rrows until screen display changes over to injection mode IV Calibrate 1 Once in purge mode press the up button to switch the device to calibration mode 2 Once in calibration mode insert injection tip...

Страница 6: ...ose when you complete the 8th dose you will need to reset the injection amount to 9 ml and proceed to inject the remaining ml proceed to inject the remaining volume refer to resetting injection dose i...

Страница 7: ...lace avoid rotating counterclockwise when inserting and removing the tip doing so will loosen the injection tip from the injection handle Open ball valve on injection tee and press start button to inj...

Страница 8: ...onger proceed to purging the device pg 6 If you want to continue injecting proceed to resetting injection dose below Power off the device by pressing the power on off button for 5 seconds until device...

Страница 9: ...al Care Storage 1 2 Daily Cleaning Thoroughly clean the device with gentle cleanser to remove any chemical residue Rinse out device at the end of each workday with at least 200 mls of water Note When...

Страница 10: ...le valve on tank reservoir and male valve on pump inlet Place in a controlled indoor enviroment After Heavy Use Follow all cleaning and lubrication protocols to maximize longetivity of all rubber seal...

Страница 11: ...dations Calibrate device at start of day and when changing products Do not let batteries fully drain Charge batteries daily preferably after end of the day and leave charging overnight Do not leave pr...

Страница 12: ...osing amount proceed to next injection site Wrong setting may be in purge mode Press arrows left or right to switch to the correct mode Product will not flow out of the injection tee with high psi rec...

Страница 13: ...will take longer to inject The product used may affect uptake time More viscous products typically take longer to inject Poor uptake conditions Poor uptake conditions very dry or very wet soils weath...

Страница 14: ...sure that the lines are free of kinks or debris Didn t prime the product through device Set device to prime mode and use priming port to run product through the lines until air bubbles have cleared De...

Страница 15: ...1 2 Replacing The Priming Port Remove by gently pulling on plug Reinsert by squeezing T shaped end and pushing gently back into place 1 2 Repairing Or Replacing Tubing Disconnect tubing by pushing in...

Страница 16: ...ors or shears Quantum Repair Instructions Repairing or Replacing Tubing Continued 1 2 Removing Cut Off Tube From Ball Valve Remove the blue collet push to connect part and then gently pull back the te...

Страница 17: ...he injection tee Add pipe sealant to the threads on the ball valve and insert the threads into the injection handle turn clockwise to tighten ball valve until hand tight 4 Insert tubing into the push...

Страница 18: ...quality and value If you are ever dissatisfied in any way please contact us so that we can address whatever concern you have Our goal is your complete satisfaction Manual www RainbowEcoscience com qu...

Отзывы: