Specifications
23
Vapor Injection Control:
Modulation Cool or Power Limit
Vapor injection valve is energized (open) continuously when
the compressor duty cycle (ON time) is 100 percent (Full
Cool). High compressor discharge temperature may cause
the vapor injection valve to energize (open) but only while
the Compressor Digital Control valve is not energized
(closed).
Compressor Discharge Temperature Control:
Vapor Injection Valve Energizes (Opens)
138 C (280 F)
Vapor Injection Valve De-energizes (Closes)
6 C (10.7 F) below energize temperature
(132 C [123 F])
Compressor Shutdown (Auto Reset)
148 C (298 F)
Vapor Injection Valve (Compressor):
Voltage
24 Vac
Current
0.85 amps
Cold Resistance
5.6 ohms
Compressor Digital Control Valve:
Voltage
24 Vac
Current Draw
0.85 amps
Water Pressure Switch (Option):
Close
117 ± 21 kPa, 1.17 ± 0.20 bar, 17 ± 3 psig
Open
35 ± 21 kPa, 0.35 ± 0.20 bar, 5 ± 3 psig
Normal R-404A System Operating Pressures (Scroll Compressor)
Container Temp.
Operating
Mode
Ambient
Temp.
Suction Pressure
Discharge Pressure
21 C (70 F)
Cool
27 to 38 C, 80
to 100 F
410 to 670 kPa, 4.10 to 6.70
bar, 59 to 97 psig
2140 to 2650 kPa, 21.40 to
26.50 bar, 310 to 385 psig
16 to 27 C, 60
to 80 F
400 to 600 kPa, 4.00 to 6.00
bar, 58 to 87 psig
1725 to 2140 kPa, 17.25 to
21.40 bar, 250 to 310 psig
2 C (35 F)
Cool
27 to 38 C, 80
to 100 F
385 to 425 kPa, 3.85 to 4.25
bar, 56 to 62 psig
1860 to 2380 kPa, 18.60 to
23.80 bar, 270 to 345 psig
16 to 27 C, 60
to 80 F
345 to 385 kPa, 3.45 to 3.85
bar, 50 to 56 psig
1450 to 1860 kPa, 14.50 to
18.60 bar, 210 to 270 psig**
-18 C (0 F)
Cool
27 to 38 C, 80
to 100 F
214 to 228 kPa, 2.14 to 2.28
bar, 31 to 33 psig
1515 to 2035 kPa, 15.15 to
20.35 bar, 220 to 295 psig**
16 to 27 C, 60
to 80 F
200 to 215 kPa, 2.00 to 2.15
bar, 29 to 31 psig
1100 to 1515 kPa, 11.00 to
15.15 bar, 160 to 220 psig**
-29 C (-20 F)
Cool
27 to 38 C, 80
to 100 F
145 to 160 kPa, 1.45 to 1.60
bar, 21 to 23 psig
1450 to 1965 kPa, 14.50 to
19.65 bar, 210 to 285 psig**
16 to 27 C, 60
to 80 F
130 to 145 kPa, 1.30 to 1.45
bar, 19 to 21 psig
1035 to 1450 kPa, 10.35 to
14.50 bar, 150 to 210 psig**
Suction and discharge pressures vary too greatly during Modulation Cool to use for evaluating or diagnosing refrigeration
system performance. During the Modulation Cool mode, the suction pressure will vary between 100 and 450 kPa, 1.0 and 4.5
bar, 15 and 65 psig depending upon the percent (percent) cooling capacity.
**Discharge pressure is determined by condenser fan cycling.
Refrigeration System Specifications (Continued)
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...