Operating Instructions
57
Data Menu
The Data menu displays general unit operating
information including sensor temperatures, unit
electrical data, etc. A complete listing of the
controller operating menu is located on an 11” x
17” foldout on the last page of the book.
NOTE: Information can ONLY be displayed
using the Data menu. Items can NOT be
changed. The screens that display on the
controller are determined by the controller
software setting and the options installed on the
unit. All screens are NOT present on all units.
Viewing the Data Menu
With the
U
NIT
O
N
/O
FF
switch
O
N
and the LCD
display showing the standard display (setpoint):
1. Press the
F4
key to directly enter the Data
menu. Menu items appear in LCD display.
2. Press the
F3
key to scroll the cursor down
through the menu list. The Data menu displays
the following functions:
•
Supply Air Temperature, Left Hand
•
Supply Air Temperature, Right Hand
•
Return Air Temperature
•
Evaporator Coil (Defrost) Temperature
•
Condenser Coil Temperature
•
Suction Pressure
•
Discharge Pressure
•
Cool Capacity
•
Ambient Temperature
•
High Pressure
•
High Pressure Temperature (Compressor
Discharge Line Temperature)
•
Relative Humidity
•
Battery Voltage
•
Voltage Average (380/460V Power
Supply)
•
Voltage 1 (Main Power Supply) (P1-P2)
•
Voltage 2 (Main Power Supply) (P2-P3)
•
Voltage 3 (Main Power Supply) (P3-P1)
•
Frequency (Main Power Supply)
•
Current Phase 1 (Main Power Supply)
•
Current Phase 2 (Main Power Supply)
•
Current Phase 3 (Main Power Supply)
•
CO
2
•
Fresh Air Exchange Rate
NOTE: Press the
5
key to lock a Data screen in
the LCD display for 5 minutes. Press any key to
unlock the display.Controller returns to previous
menu level or LCD Standard Display after 30
seconds.
Figure 32: Data Menu
DATA
MAIN MENU
- Supply LH
- Supply RH
- Return
- Evaporator
- Condensor
- Suct. Press
- Disch. Press
- Cool Cap.
- Ambient
- High Press
- High Pr Tmp
- Hum Val.
- Bat. Voltage
- Voltage
- Volt P1 P2
- Volt P2 P3
- Volt P3 P1
- Frequency
- Zero Curr
- Curr. Ph. 1
- Curr. Ph. 2
- Curr. Ph. 3
- CO2
- Fresh Air Exchange Rate
Data Menu
RMM STATE
DATALOGGER
CONFIGURATION
MISC. FUNCTIONS
COMMANDS
ALARMS
NOTE: All screens are NOT
present on all units. The
screens that display on the
controller are determined by
the Controller Software
settings and the options
installed on the unit.
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...