Operating Instructions
66
Unit Type:
View display value (factory default =
NO HUM). Controller automatically activates
when a humidity sensor is installed for more than
1 minute. Setting this value is not necessary.
Pressure Sensor:
Sets the pressure sensor to
NONE, LOW, HIGH, HIGH+LOW.
Zero Current:
Displays zero current On or Off.
Supply LH:
View display on or off value (factory
default = off). Controller automatically activates
when a left hand supply sensor is installed for
more than 1 minute. Setting this value is not
necessary.
AFAM Option:
Sets the Advanced Fresh Air
Management System to None, AFAM, AFAM+ or
Log.FAE (factory default = None). Controller
automatically activates when an AFAM system
vent door and/or AFAM+ gas sensor is installed
for more than one minute. Setting this value is not
necessary.
Gas Analyzer:
Select type of gas sensor.
AFAM Units:
Displays whether the fresh air
exchange rate will be displayed in cubic meters
per hour or cubic feet per min.
AFAM Type:
Selects the type of AFAM motor.
NONE = No AFAM. FEEDBACK =
potentiometer motor. TIMING CUR current
measuring motor. (factory default = TIMING
CUR).
Evaporator Type:
Sets the evaporator fan value to
3 fan or 2 fan.
Condenser Type:
Sets the condenser fan value to
1/2 HP, 3/4 HP or 2 HP. Must be manually set.
Chart R (Electronic Chart Recorder):
Must be
manually set to -20 +80 F 31 day, -30 +25 C 31
day, -25 + 25 C 31 day or Not Present.
Auto Configuration:
View display on or off value
(factory default = off). Set value to on to
automatically configure unit to installed
components. See “Automatic Configuration of
Spare Parts Controller” in this chapter for
additional information.
Unit #:
Is the TK serial number of the unit itself.
This is a ten digit alpha / numeric entry found
under the UNIT Serial Number on the Serial Plate
on the unit.
Unit ID:
A 12 digit alpha / numeric container
number.
NOTE: MAGNUM units without a container
number beginning with MAE, MSF or MWC
must be set for USDA temperature sensing. See
“USDA Type” above.
5. To set a new Configuration screen value:
a. Press the
F4
key with cursor in the desired
menu line. The Password screen appears.
b. Press the
F2
key,
A
key (password is “A”),
F4
key and then the
E
XIT
key. An Enter
Arrow appears in the hourmeter line.
c. Use the general purpose keypad to enter
the desired value; or press the
F3
key to
toggle the value to the desired setting.
d. Press the
F4
key and release when the
entry is complete. Press the
E
XIT
key. The
new value appears in the menu line.
6. Repeat steps 4 and 5 to reset additional
configuration values.
7. Press the
ESC
key to exit the Configurations
screen.
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...