Operating Instructions
92
5. With the mode setting in the menu line, press
and hold the F4 key until the cursor stops
flashing. The new mode setting will appear on
the LCD display.
6. When settings are completed, press the ESC
key to exit the setpoint menu.
Changing the AFAM+ Settings
Using ‘OPTISET’ (sets ‘DEMAND’
Mode)
1. Press Setpoint key. The setpoint menu
appears with the cursor on the ‘OPTISET’
line.
2. Press F4 key. The following screen will
appear:
3. Use F2 / F3 keys to scroll to desired product.
4. Press and hold F4 key to auto enter product
settings.
5. Display will show selected product.
NOTE: If any of the auto product settings
made by ‘Optiset’ are modified, the display
will now change from the selected product to
‘CUSTOM’. This signifies that some or all of
the settings have been changed.
Modify Optiset Product Settings in
‘DEMAND’
1. Press Setpoint key. The setpoint menu appears
with the cursor on the ‘OPTISET’ line.
2. Press F3 key and scroll to the setting to be
modified. Settings that can be modified:
•
Temperature Setpoint
NOTE: Setpoint changes > 5° C (9° F) will
force the CO2 setting to 1%, O2 setting to
20%, cancel the AFAM DELAY and switch
OFF Bulb Mode, Economy Mode, Humidity
Control and Humidity Setpoint.
•
Bulb Mode
•
Evaporator Fan Speed
•
Defrost Termination Temperature
•
Economy Mode
•
Humidity Control
•
Humidity Setpoint
•
AFAM DELAY
•
O2 Minimum (if applicable)
•
CO2 Maximum
NOTE: Do not modify any of the above
settings without direct instructions from the
shipper. Serious cargo damage could occur.
3. Example. Modifying the O2 and CO2 settings:
4. Press F3 key to scroll to ‘O2 MIN’.
5. Press F4 key to enter the setting mode.
6. Enter the O2 setting supplied by the shipper.
7. Press and hold the F4 key until the cursor
stops flashing. The new rate is recorded in the
datalogger and appears on the LCD display.
8. Press F3 key to scroll to ‘CO2 MAX’.
9. Press F4 key to enter the setting mode.
10. Enter the CO2 setting supplied by the shipper.
11. Press and hold the F4 key until the cursor
stops flashing. The new rate is recorded in the
datalogger and appears on the LCD display.
Changing the AFAM Mode to
‘DEMAND’
1. Press Setpoint key. The setpoint menu appears
with the cursor on the ‘OPTISET’ line.
2. Press F3 key and scroll to the ‘AFAM’ line.
3. Press F4 key. Cursor moves to the end of the
command line and flashes.
4. Press F2 key to toggle to ‘DEMAND’.
5. With ‘DEMAND’ in the menu line, press and
hold the F4 key until the cursor stops flashing.
6. Press F3 key to scroll to ‘CO2 MAX’.
7. Press F4 key to enter the setting mode.
8. Enter the CO2 setting supplied by the shipper.
OPTISET
APPLES - GENERAL
TO ACTIVATE PRESS F4
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...