background image

REMOVAL

PROCEDURE

S E R V I C E   M A N U A L

Indoor Unit

Non-Inverter

Floor Standing Type

3/4/5 HP Class

Si241306

Содержание FVY100LAVE

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Non Inverter Floor Standing Type 3 4 5 HP Class Si241306 ...

Страница 2: ...Service Manual Removal Procedure Indoor Unit Applicable Models zCooling Only FV125LAVE zHeat Pump FVY71LAVE FVY100LAVE FVY125LAVE ...

Страница 3: ...tents 1 Procedure to Remove Suction Grille and Air Filter 2 2 Procedure to Remove Electric Parts and Remote Controller 4 3 Procedure to Remove Fan Rotor and Fan Motor 6 4 Procedure to Remove Swing Motor 7 5 Procedure to Remove Heat Exchanger 8 ...

Страница 4: ... to Remove Suction Grille and Air Filter Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points Removing air filter 1 Pull tabs of suction grille to open the grille slightly 2 Lift up air filter Air Filter ...

Страница 5: ...e and Air Filter Removal Procedure 3 Removing suction grille 1 Remove 2 fixing screws located at both left and right sides of suction grille 2 Open widely and lift suction grille to remove it Step Procedure Points Suction grille stopper Screws ...

Страница 6: ...work Step Procedure Points 1 To remove switch box cover dismount screw A loosen screw B and slide the cover to right side Remove suction air thermistor from bell mouth 2 The figure right shows part layout inside switch box 3 Disconnect remote controller cord from switch box Switch box cover A A B Capacitor for fan Control PCB Power supply PCB Remote controller terminal strip Heat exchanger thermis...

Страница 7: ...emote Controller Removal Procedure 5 4 Remove 2 screws to dismount front panel 5 Remove 4 screws to dismount remote controller Step Procedure Points Remote controller Remote controller fixing plate Remote controller cord Remote controller cover Hooks ...

Страница 8: ... plate to disassemble fan rotor Caution When reassembling be sure to clamp wires Removing fan motor 1 Disconnect lead wire for fan motor and harness for capacitor from switch box 2 To dismount pipe fixing plate remove a screw and slide the plate to left side 3 To remove wire fixing plate remove 2 screws and slide the plate upward 4 Remove 4 hexagon head screws to dismount fan motor Fan rotor Bell ...

Страница 9: ...move 4 screws to dismount discharge assembly 3 Remove 2 screws to dismount swing motor assembly Caution 2 of 8 horizontal blades located at top and bottom position can be moved by hand individually while rest 6 blades are linked to move by hand at the same time 4 Disengage hooks on swing motor mounting plate cover and remove 2 screws Then remove swing motor Harness for swing motor Harness for limi...

Страница 10: ... 1 Disconnect connector for swing motor and 1 for limit switch 2 Remove heat exchanger thermistor from PCB 3 Remove 3 mounting screws to dismount switch box and air partition plate Removing top panel 1 Remove 8 screws to dismount top panel Removing heat exchanger 1 Remove 4 screws to dismount heat exchanger Caution Be sure to remove heat exchanger before cleaning it Top panel Air partition plate S...

Страница 11: ...Revision History Month Year Version Revised contents 01 2013 Si241306 First edition ...

Страница 12: ...oduct The User s Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor and or retailer Cautions on product corrosion 1 Air conditioners should not be installed in areas where corrosive gases such as acid gas or alkaline gas are produced 2 If the outdoor unit is to be inst...

Отзывы: